Hi Tobias,

Am 16.10.23 um 19:11 schrieb Tobias Burnus:
Yesterday, someone was confused because the signal handler did not work.

It turned out that the created Fortran procedure used as handler used
pass by reference - and 'signal' passed the it by value.

This patch adds the 'passed by value' to the wording:

"@var{HANDLER} to be executed with a single integer argument passed by
value"

OK for mainline?

I think the patch qualifies as obvious.

While at it, you might consider removing the comment a few lines below
the place you are changing,

@c TODO: What should the interface of the handler be?  Does it take
arguments?

and enhance the given example by e.g.:

subroutine handler_print (signal_number)
  integer, value :: signal_number
  print *, "In handler_print: received signal number", signal_number
end subroutine handler_print

Thanks,
Harald