On 8/16/23 02:33, Philipp Tomsich wrote:
It seems reasonable from an encoding standpoint. But I haven't been able to convince the assembler to encode a 0 into the pred/succ fields.Could we use the underlying 'fence' instruction (unless the assembler rejects the specific form that is needed) instead of the hex-insn? Should this also check HAVE_AS_MARCH_ZIHINTPAUSE (which must then also be added to configure.ac)?