On 07/25/2015 04:16 PM, Patrick Palka wrote:
On Sat, Jul 25, 2015 at 7:12 PM, Patrick Palka <patr...@parcs.ath.cx> wrote:
gcc/cp/ChangeLog:

         PR c++/66857
         * cvt.c (ocp_convert): Don't call scalar_constant_value when
         converting to a class type.

gcc/testsuite/ChangeLog:

         PR c++/66857
         * g++.dg/init/pr66857.C: New test.

This fix was approved here https://gcc.gnu.org/bugzilla/show_bug.cgi?id=66857#c5

Committed to mainline.  Is it OK for the GCC 5 branch?

Yes, thanks.

Jason