i meant you switched PCMA and PCMU... T.
2009/10/23 Georgiewskiy Yuriy <[email protected]> > On 2009-10-23 10:16 +0200, Tihomir Culjaga wrote > [email protected]...: > > TC>> TC> > TC>> TC>it is gonna be easier to track. > TC>> TC> > TC>> TC>Tomorrow i will test on 1.0.4 but please lets move to trunk. > TC>> > TC>> i make it a bit later, to move tickets to jira and source to svn i > TC>> need some time to undertand how this system is works, especially jira. > TC>> > TC>> > TC>audio issue is better now :) > TC> > TC>however i have a few questions: > TC> > TC>1. can we control codec framing size via config file setting (e.g. > PCMA:20, > TC>PCMU:20)? > > at this time i think no, there is a number issues in codec part now. > > TC>2. can we control tunneling via config file setting? > > at this time no, i implement it later. > > TC>3. can we control mediaWaitForConnect flag within setup message via > config > TC>file setting? > > what is mediaWaitForConnect flag, may be another trmin in h323? > > TC>Now, when i can test more and place outgoing calls to different > equipment, i > TC>found that there is an issue when we get h.225 progress without a > fastStart > TC>element. > TC> > TC>Here is a tshark: > TC> > TC> 5.242526 10.4.62.7 -> 10.4.4.254 H.225.0 CS: setup > OpenLogicalChannel > TC> > TC> 5.243982 10.4.4.254 -> 10.4.62.7 H.225.0 CS: callProceeding > TC> 10.512617 10.4.4.254 -> 10.4.62.7 H.225.0 CS: progress > TC> 10.983697 10.4.4.254 -> 10.4.62.7 H.225.0 CS: alerting > TC> 20.002796 10.4.4.254 -> 10.4.62.7 H.225.0 CS: connect > TC> 20.002981 10.4.4.254 -> 10.4.62.7 H.225.0/H.245 CS: facility > TC>terminalCapabilitySet > TC> 20.003210 10.4.4.254 -> 10.4.62.7 H.225.0/H.245 CS: facility > TC>masterSlaveDetermination > TC> 31.472362 10.4.4.254 -> 10.4.62.7 H.225.0/H.245 CS: > releaseComplete > TC>endSessionCommand > TC> > TC> > TC>the terminating GW didn't include a faststart element within a > returning > TC>h.225 message we didn't match the capabilities (framing of them) in our > TC>setup (and you are waiting an open LC to start pre_answer).... so now, > the > TC>terminator is waiting for the originator to start exchanging TCS/MSD. As > TC>tunneling is true, this should be done using h.225 Facility messages. > TC> > TC> > TC>your behavior should be like this: > TC> > TC> 5.242526 10.4.62.7 -> 10.4.4.254 H.225.0 CS: setup > TC>OpenLogicalChannel g711A with 30 ms > TC> 5.243982 10.4.4.254 -> 10.4.62.7 H.225.0 CS: callProceeding > TC> 10.512617 10.4.4.254 -> 10.4.62.7 H.225.0 CS: progress > TC> > TC> 10.4.62.7 -> 10.4.4.254 H.225.0/H.245 CS: > facility > TC>terminalCapabilitySet > TC> 10.4.62.7 -> 10.4.4.254 H.225.0/H.245 CS: > facility > TC>masterSlaveDetermination > TC> > TC> 10.4.4.254 -> 10.4.62.7 H.225.0/H.245 CS: > facility > TC>terminalCapabilitySet > TC> 10.4.4.254 -> 10.4.62.7 H.225.0/H.245 CS: > facility > TC>masterSlaveDetermination > TC> > TC> 10.4.4.254 -> 10.4.62.7 H.225.0/H.245 CS: > facility > TC>terminalCapabilitySetAck > TC> 10.4.4.254 -> 10.4.62.7 H.225.0/H.245 CS: > facility > TC>masterSlaveDeterminationAck > TC> > TC> 10.4.62.7 -> 10.4.4.254 H.225.0/H.245 CS: > facility > TC>terminalCapabilitySetAck > TC> 10.4.62.7 -> 10.4.4.254 H.225.0/H.245 CS: > facility > TC>masterSlaveDeterminationAck > TC> > TC> 10.4.62.7 -> 10.4.4.254 H.225.0/H.245 CS: > facility > TC>openlogicalchannel (g711A) > TC> 10.4.4.254 -> 10.4.62.7 H.225.0/H.245 CS: > facility > TC>openlogicalchannel (g711A) > TC> > TC> 10.4.62.7 -> 10.4.4.254 H.225.0/H.245 CS: > facility > TC>openlogicalchannelAck > TC> 10.4.4.254 -> 10.4.62.7 H.225.0/H.245 CS: > facility > TC>openlogicalchannelAck > TC> > TC> <now you can start pre_answer!> > TC> > TC> 10.983697 10.4.4.254 -> 10.4.62.7 H.225.0 CS: alerting > TC>... > > may bee, while i in hospital i have a very limited ways for testing, > especially for inbound calls throuce h323. i find one issues in signaling > part in h323plus, src/h323.cxx grep "Very Frustrating - S.H." try uncomment > fast start handling there, may be it help. > > C уважением With Best Regards > Георгиевский Юрий. Georgiewskiy Yuriy > +7 4872 711666 +7 4872 711666 > факс +7 4872 711143 fax +7 4872 711143 > Компания ООО "Ай Ти Сервис" IT Service Ltd > http://nkoort.ru http://nkoort.ru > JID: [email protected] JID: [email protected] > YG129-RIPE YG129-RIPE > > _______________________________________________ > FreeSWITCH-users mailing list > [email protected] > http://lists.freeswitch.org/mailman/listinfo/freeswitch-users > UNSUBSCRIBE:http://lists.freeswitch.org/mailman/options/freeswitch-users > http://www.freeswitch.org > >
_______________________________________________ FreeSWITCH-users mailing list [email protected] http://lists.freeswitch.org/mailman/listinfo/freeswitch-users UNSUBSCRIBE:http://lists.freeswitch.org/mailman/options/freeswitch-users http://www.freeswitch.org
