Counters 1 and 2 of the 8254 are cascaeded to create the 32-bit timer
used for the analog input pacer trigger. The base clock to these counters
is 10 MHz.
Counter 0 is available to the user for general purpose use. This counter
can use either an internal 1 MHz clock or an external clock. The
(*insn_config) for the counter subdevice provides support for
INSN_CONFIG_{SET,GET}_CLOCK_SRC to allow the user to select the
clock source to use. Fix the INSN_CONFIG_GET_CLOCK_SRC so it returns
the correct speed of the internal clock.
Signed-off-by: H Hartley Sweeten <[email protected]>
Cc: Ian Abbott <[email protected]>
Cc: Greg Kroah-Hartman <[email protected]>
---
drivers/staging/comedi/drivers/adv_pci1710.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/staging/comedi/drivers/adv_pci1710.c
b/drivers/staging/comedi/drivers/adv_pci1710.c
index c5f8bff..9e45f3d 100644
--- a/drivers/staging/comedi/drivers/adv_pci1710.c
+++ b/drivers/staging/comedi/drivers/adv_pci1710.c
@@ -701,7 +701,7 @@ static int pci1710_counter_insn_config(struct comedi_device
*dev,
data[2] = 0;
} else {
data[1] = 0;
- data[2] = I8254_OSC_BASE_10MHZ;
+ data[2] = I8254_OSC_BASE_1MHZ;
}
break;
default:
--
2.5.1
_______________________________________________
devel mailing list
[email protected]
http://driverdev.linuxdriverproject.org/mailman/listinfo/driverdev-devel