Use power_supply_put() to decrement the power supply's device reference counter.
Signed-off-by: Krzysztof Kozlowski <[email protected]> Reviewed-by: Bartlomiej Zolnierkiewicz <[email protected]> Reviewed-by: Sebastian Reichel <[email protected]> Acked-by: Robert Jarzmik <[email protected]> --- arch/arm/mach-pxa/raumfeld.c | 4 +++- 1 file changed, 3 insertions(+), 1 deletion(-) diff --git a/arch/arm/mach-pxa/raumfeld.c b/arch/arm/mach-pxa/raumfeld.c index a762b23ac830..6dc4f025e674 100644 --- a/arch/arm/mach-pxa/raumfeld.c +++ b/arch/arm/mach-pxa/raumfeld.c @@ -758,8 +758,10 @@ static void raumfeld_power_signal_charged(void) struct power_supply *psy = power_supply_get_by_name(raumfeld_power_supplicants[0]); - if (psy) + if (psy) { power_supply_set_battery_charged(psy); + power_supply_put(psy); + } } static int raumfeld_power_resume(void) -- 1.9.1 _______________________________________________ devel mailing list [email protected] http://driverdev.linuxdriverproject.org/mailman/listinfo/driverdev-devel