Hi,

On Thu, Jul 24, 2025 at 04:02:54PM +0800, Damon Ding wrote:
> In order to move the parnel/bridge parsing and attachmenet to the
> Analogix side, add component struct drm_bridge *bridge to platform
> data struct analogix_dp_plat_data.
> 
> The movemenet makes sense because the panel/bridge should logically
> be positioned behind the Analogix bridge in the display pipeline.
> 
> Signed-off-by: Damon Ding <[email protected]>
> ---
>  include/drm/bridge/analogix_dp.h | 1 +
>  1 file changed, 1 insertion(+)
> 
> diff --git a/include/drm/bridge/analogix_dp.h 
> b/include/drm/bridge/analogix_dp.h
> index cf17646c1310..15cb6b706e9f 100644
> --- a/include/drm/bridge/analogix_dp.h
> +++ b/include/drm/bridge/analogix_dp.h
> @@ -27,6 +27,7 @@ static inline bool is_rockchip(enum analogix_dp_devtype 
> type)
>  struct analogix_dp_plat_data {
>       enum analogix_dp_devtype dev_type;
>       struct drm_panel *panel;
> +     struct drm_bridge *bridge;
>       struct drm_encoder *encoder;
>       struct drm_connector *connector;
>       bool skip_connector;

So it's not the analogix_dp bridge, but the bridge after that if any?

You should probably change it to next_bridge to avoid any confusion.

Maxime

Attachment: signature.asc
Description: PGP signature