On 3/16/2022 9:45 AM, Sankeerth Billakanti (QUIC) wrote:
Subject: Re: [RFC PATCH v2 4/5] drm/msm/dp: replace dp_connector with
drm_bridge_connector
Date: Wed, 23 Feb 2022 16:40:56 -0800
From: Kuogee Hsieh <[email protected]>
To: Stephen Boyd <[email protected]>, Dmitry Baryshkov
<[email protected]>
CC: Abhinav Kumar <[email protected]>, Bjorn Andersson
<[email protected]>, Rob Clark <[email protected]>, Sean Paul
<[email protected]>, David Airlie <[email protected]>, Daniel Vetter
<[email protected]>, [email protected], dri-
[email protected], [email protected]


On 2/23/2022 1:33 PM, Stephen Boyd wrote:
Quoting Kuogee Hsieh (2022-02-23 10:27:26)
On 2/23/2022 10:22 AM, Dmitry Baryshkov wrote:
On 23/02/2022 20:21, Kuogee Hsieh wrote:

In the panel device node.

Can you please share it too?

&soc {
           edp_power_supply: edp_power {
                   compatible = "regulator-fixed";
                   regulator-name = "edp_backlight_power";

                   regulator-always-on;
                   regulator-boot-on;
           };

           edp_backlight: edp_backlight {
                   compatible = "pwm-backlight";

                   pwms = <&pm8350c_pwm 3 65535>;
                   power-supply = <&edp_power_supply>;
                   enable-gpio = <&pm8350c_gpios 7 GPIO_ACTIVE_HIGH>;

                   pinctrl-names = "default";
                   pinctrl-0 = <&backlight_pwm_default>;
           };

           edp_panel: edp_panel {
                   compatible = "sharp_lq140m1jw46";
Is that supposed to be sharp,lq140m1jw46 with a comma instead of an
underscore?

Stephen,

This is our internal branch which does not have patches up to date yet.

I will cherry-pick newer edp related patches which are under review now to
re test it.

Tested-by: Sankeerth Billakanti <[email protected]>
Reviewed-by: Abhinav Kumar <[email protected]>

Detect returned eDP not connected because the panel power was not on and 
mode_valid was failing because the DP mode_valid is different from eDP

Reply via email to