Dne torek, 04. september 2018 ob 11:18:47 CEST je Chen-Yu Tsai napisal(a):
> On Sun, Sep 2, 2018 at 3:27 PM Jernej Skrabec <[email protected]> 
wrote:
> > Allwinner H6 SoC has multiplier N range between 1 and 254. Since parent
> > rate is 24MHz, intermediate result when calculating final rate easily
> > overflows 32 bit variable.
> > 
> > Because of that, introduce function for calculating clock rate which
> > uses 64 bit variable for intermediate result.
> > 
> > Signed-off-by: Jernej Skrabec <[email protected]>
> 
> The code looks good. The A80's Video PLLs are also affected by this.
> The range for N on the A80 is 12 ~ 255.
> 
> Can you add fixes and stable tags?

Sure.

> 
> ChenYu