Em Thu, 13 Jul 2017 13:50:20 +0100
Kieran Bingham <[email protected]> escreveu:

> On 26/06/17 19:12, Laurent Pinchart wrote:
> > The sink pointer is used to configure routing inside the VSP, and as
> > such must point to the next VSP entity in the pipeline. The WPF being a
> > pipeline terminal sink, its output route can't be configured. The
> > routing configuration code already handles this correctly without
> > referring to the sink pointer, which thus doesn't need to be set.
> > 
> > Signed-off-by: Laurent Pinchart <[email protected]> 
> >  
> 
> Reviewed-by: Kieran Bingham <[email protected]>

Acked-by: Mauro Carvalho Chehab <[email protected]>


Thanks,
Mauro