On 10.03.2017 05:32, Sean Paul wrote:
> From: zain wang <[email protected]>
>
> The bridge does not need to be powered in analogix_dp_bind(), so
> remove the calls to pm_runtime_get()/phy_power_on()/analogix_dp_init_dp()
> as well as their power-off counterparts.
>
> Cc: Stéphane Marchesin <[email protected]>
> Signed-off-by: zain wang <[email protected]>
> Signed-off-by: Caesar Wang <[email protected]>
> [the patch originally just removed the power_on portion, seanpaul removed
> the power off code as well as improved the commit message]
> Signed-off-by: Sean Paul <[email protected]>

Reviewed-by: Andrzej Hajda <[email protected]>
--
Regards
Andrzej