On 11/2/21 7:25 am, Gedare Bloom wrote: > On Wed, Feb 10, 2021 at 9:56 AM Joel Sherrill <j...@rtems.org > <mailto:j...@rtems.org>> wrote: > On Wed, Feb 10, 2021, 10:53 AM Sebastian Huber > <sebastian.hu...@embedded-brains.de > <mailto:sebastian.hu...@embedded-brains.de>> wrote: > On 10/02/2021 17:47, Joel Sherrill wrote: > > On Wed, Feb 10, 2021, 10:30 AM Sebastian Huber > > <sebastian.hu...@embedded-brains.de > <mailto:sebastian.hu...@embedded-brains.de> > > <mailto:sebastian.hu...@embedded-brains.de > <mailto:sebastian.hu...@embedded-brains.de>>> wrote: > > > > On 10/02/2021 07:53, Sebastian Huber wrote: > > > > > Hello, > > > > > > I try to update the clock manager documentation and noticed > that > > there > > > is no time zone specified for the RTEMS epoch. In the > timecounter > > > initialization we use: > > > > > > static struct timehands th0 = { > > > [...] > > > #ifdef __rtems__ > > > .th_bintime = { .sec = TOD_SECONDS_1970_THROUGH_1988 }, > > > .th_microtime = { TOD_SECONDS_1970_THROUGH_1988, 0 }, > > > .th_nanotime = { TOD_SECONDS_1970_THROUGH_1988, 0 }, > > > .th_boottime = { .sec = TOD_SECONDS_1970_THROUGH_1988 - 1 > }, > > > #endif /* __rtems__ */ > > > > > > [...] > > > > > > }; > > > > > > Since Unix epoch is 1970-01-01T00:00:00Z, this basically > defines > > that > > > the RTEMS epoch is 1988-01-01T00:00:00Z. Should this be > documented? > > > The current implementation also implies that the time > reported by > > > RTEMS is in UTC (modulo leap seconds). > > > > I tried to document the clocks provided by RTEMS, see tail of > > (glossary.rst): > > > > > https://lists.rtems.org/pipermail/devel/2021-February/064451.html > <https://lists.rtems.org/pipermail/devel/2021-February/064451.html> > > > <https://lists.rtems.org/pipermail/devel/2021-February/064451.html > <https://lists.rtems.org/pipermail/devel/2021-February/064451.html>> > > > > > > Is it sufficient to reference the epoch entry in various clock get > > time method pages? > The relevant epoch and clock is now referenced in the directives. > > > > And should there be discussion somewhere about TZ environment > variable > > and the methods in newlib which account for that. > I think a time zone is simply not accounted for in the RTEMS Classic > API. With the setting above I guess the time zone is fixed to UTC. > > > By default clock_gettime is also UTC. You have to go through the C Library > time methods to get timezones > > This is an interesting topic. I would wager to guess that most users > implicitly > assumed their own timezone/time basis (and likely didn't care, as long it was > consistent).
In my PTP testing I set the global TZ environment variable to AEST and date etc all worked nicely. Chris _______________________________________________ devel mailing list devel@rtems.org http://lists.rtems.org/mailman/listinfo/devel