Hi

Looking at failures from a build sweep.

I think this one is known but am passing along. The rtbx4925, rtbx4938,
and hurricane fail with this:

   -o dl04.exe init.o dl-load.o dl-cpp.o dl-tar.o dl-sym.o
/data/home/joel/rtems-4.11-work/tools/4.12/bin/../lib/gcc/mips-rtems4.12/6.1.1/../../../../mips-rtems4.12/bin/ld:
dl-sym.o: compiled for a big endian system and target is little endian
/data/home/joel/rtems-4.11-work/tools/4.12/bin/../lib/gcc/mips-rtems4.12/6.1.1/../../../../mips-rtems4.12/bin/ld:
dl-sym.o: endianness incompatible with that of the selected emulation
/data/home/joel/rtems-4.11-work/tools/4.12/bin/../lib/gcc/mips-rtems4.12/6.1.1/../../../../mips-rtems4.12/bin/ld:
failed to merge target specific data of file dl-sym.o

I am adding dl03-dl05 to the file
testsuites/testdata/dltests-broken-on-this-bsp.tcfg
but wanted to report this in case there was discussion.

--joel
_______________________________________________
devel mailing list
devel@rtems.org
http://lists.rtems.org/mailman/listinfo/devel

Reply via email to