Hi Looking at failures from a build sweep.
I think this one is known but am passing along. The rtbx4925, rtbx4938, and hurricane fail with this: -o dl04.exe init.o dl-load.o dl-cpp.o dl-tar.o dl-sym.o /data/home/joel/rtems-4.11-work/tools/4.12/bin/../lib/gcc/mips-rtems4.12/6.1.1/../../../../mips-rtems4.12/bin/ld: dl-sym.o: compiled for a big endian system and target is little endian /data/home/joel/rtems-4.11-work/tools/4.12/bin/../lib/gcc/mips-rtems4.12/6.1.1/../../../../mips-rtems4.12/bin/ld: dl-sym.o: endianness incompatible with that of the selected emulation /data/home/joel/rtems-4.11-work/tools/4.12/bin/../lib/gcc/mips-rtems4.12/6.1.1/../../../../mips-rtems4.12/bin/ld: failed to merge target specific data of file dl-sym.o I am adding dl03-dl05 to the file testsuites/testdata/dltests-broken-on-this-bsp.tcfg but wanted to report this in case there was discussion. --joel
_______________________________________________ devel mailing list devel@rtems.org http://lists.rtems.org/mailman/listinfo/devel