Which BSP is affected by this?
On 18/01/16 00:19, Joel Sherrill wrote:
Hi
With the recent clock changes, I am noticing that on some BSPs
ticker is reporting times 4, 9, 14, ... instead of 5, 10, 15.
It looks like the time is 4.9999999 when it should simply be 5 so
ticker just reports 4.
Given this is a visible change in behavior, I would like to know
what causes it and how it can be resolved?
Thanks.
--joel