Hi Looks like the benchmark timer code on the virtex5 is not 100% right. It is missing a symbol.
/users/joel/rtems-4.11-work/rtems-testing/rtems/build-powerpc-virtex5-rtems/powerpc-rtems4.11/c/virtex5/lib/libcpu/powerpc/../../../../../../../rtems/c/src/lib/libcpu/powerpc/mpc6xx/timer/timer.c:77: undefined reference to `BSP_Convert_decrementer' ../../../../../virtex5/lib/librtemsbsp.a(timer.rel): In function `Read_long_timer': /users/joel/rtems-4.11-work/rtems-testing/rtems/build-powerpc-virtex5-rtems/powerpc-rtems4.11/c/virtex5/lib/libcpu/powerpc/../../../../../../../rtems/c/src/lib/libcpu/powerpc/mpc6xx/timer/timer.c:85: undefined reference to `BSP_Convert_decrementer' collect2: error: ld returned 1 exit status -- Joel Sherrill, Ph.D. Director of Research & Development joel.sherr...@oarcorp.com On-Line Applications Research Ask me about RTEMS: a free RTOS Huntsville AL 35805 Support Available (256) 722-9985 _______________________________________________ devel mailing list devel@rtems.org http://lists.rtems.org/mailman/listinfo/devel