Hi

Looks like the benchmark timer code on the virtex5 is not 100%
right. It is missing a symbol.

/users/joel/rtems-4.11-work/rtems-testing/rtems/build-powerpc-virtex5-rtems/powerpc-rtems4.11/c/virtex5/lib/libcpu/powerpc/../../../../../../../rtems/c/src/lib/libcpu/powerpc/mpc6xx/timer/timer.c:77:
undefined reference to `BSP_Convert_decrementer'
../../../../../virtex5/lib/librtemsbsp.a(timer.rel): In function
`Read_long_timer':
/users/joel/rtems-4.11-work/rtems-testing/rtems/build-powerpc-virtex5-rtems/powerpc-rtems4.11/c/virtex5/lib/libcpu/powerpc/../../../../../../../rtems/c/src/lib/libcpu/powerpc/mpc6xx/timer/timer.c:85:
undefined reference to `BSP_Convert_decrementer'
collect2: error: ld returned 1 exit status

-- 