Oriel Maute created MTOMCAT-305:
-----------------------------------

             Summary: shutdown not correct working if embedded tomcat is 
started twice
                 Key: MTOMCAT-305
                 URL: https://issues.apache.org/jira/browse/MTOMCAT-305
             Project: Apache Tomcat Maven Plugin
          Issue Type: Bug
          Components: tomcat7
    Affects Versions: 2.2
         Environment: multi-module project
            Reporter: Oriel Maute
            Assignee: Olivier Lamy (*$^¨%`£)


We have a multi-module project with the modules A and B. 
In module A we start and stop an embedded tomcat server within our integration 
tests; same in module B. 

The integration-tests for module A work perfectly. But after this, the start of 
the embedded tomcat server for module B is not working because the port 8080 is 
still in use from the integration test of module A. 
The reason is that the shutdown on module A invokes on the Catalina Container 
the "stop()" method, this method does not unbind the port 8080. 
I think - specially in this scenario - the shutdown mojo should invoke the 
"destroy()" method on the Catalina Container. If this is not possible in every 
case, it would be great to have a parameter for the shutdown goal to specify if 
"stop" or "destroy" should be called on the Catalina Container.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

---------------------------------------------------------------------
To unsubscribe, e-mail: dev-unsubscr...@tomcat.apache.org
For additional commands, e-mail: dev-h...@tomcat.apache.org

Reply via email to