Oriel Maute created MTOMCAT-305: ----------------------------------- Summary: shutdown not correct working if embedded tomcat is started twice Key: MTOMCAT-305 URL: https://issues.apache.org/jira/browse/MTOMCAT-305 Project: Apache Tomcat Maven Plugin Issue Type: Bug Components: tomcat7 Affects Versions: 2.2 Environment: multi-module project Reporter: Oriel Maute Assignee: Olivier Lamy (*$^¨%`£)
We have a multi-module project with the modules A and B. In module A we start and stop an embedded tomcat server within our integration tests; same in module B. The integration-tests for module A work perfectly. But after this, the start of the embedded tomcat server for module B is not working because the port 8080 is still in use from the integration test of module A. The reason is that the shutdown on module A invokes on the Catalina Container the "stop()" method, this method does not unbind the port 8080. I think - specially in this scenario - the shutdown mojo should invoke the "destroy()" method on the Catalina Container. If this is not possible in every case, it would be great to have a parameter for the shutdown goal to specify if "stop" or "destroy" should be called on the Catalina Container. -- This message was sent by Atlassian JIRA (v6.3.4#6332) --------------------------------------------------------------------- To unsubscribe, e-mail: dev-unsubscr...@tomcat.apache.org For additional commands, e-mail: dev-h...@tomcat.apache.org