Hi Łukasz, Thanks for quick reply and a quick update.
I followed the guideline ...got a bit confused on the logging of the rtt2pty tool: ../tools-rtt2pty/rtt2pty -b btmonitor Using jlinkarm found at /opt/SEGGER/JLink/libjlinkarm.so Connected to: J-Link OB-SAM3U128-V2-NordicSemi compiled Jul 12 2018 11:44:41 S/N: 683623237 Searching for RTT control block... Failed to find matching up-buffer Running it without the -b btmonitor I could get a pty port. Monitoring showed some logging, not like the one from the codecoup btmon link but a starting point. 021819 Extended adv: 'conn' incomplete rssi=-60 txpower=127, pphy=1, sphy=1, sid=10, addr_type=0 addr=66:55:44:33:22:11 021822 length_data=229 data=0x19:0x09:0x48:0x65:0x6c:0x6c:0x6f:0x2c:0x20:0x49:0x27:0x6d:0x20:0x61:0x64:0x76:0x65:0x72:0x74:0x69:0x7 .... 021853 Extended adv: 'conn' complete rssi=-60 txpower=127, pphy=1, sphy=1, sid=10, addr_type=0 addr=66:55:44:33:22:11 021856 length_data=15 data=0x69:0x6e:0x67:0x20:0x39:0x19:0x09:0x48:0x65:0x6c:0x6c:0x6f:0x2c:0x20:0x49 fields: 021859 021859 Extended adv: 'conn' incomplete rssi=-53 txpower=127, pphy=1, sphy=1, sid=10, addr_type=0 addr=66:55:44:33:22:11 021862 length_data=229 data=0x19:0x09:0x48:0x65:0x6c:0x6c:0x6f:0x2c:0x20:0x49:0x27:0x6d:0x20:0x61:0x64:0x76:0x65:0x72:0x74:0x69:0x7 .... .... 021861 received advertisement; event_type=4 rssi=-82 addr_type=1 addr=f1:80:b4:61:d2:c6 length_data=29 data=0x02:0x0a:0x04:0x19:0x09:0x45:0x78:0x70:0x65:0x72:0x74:0x26:0x4d:0x69:0x6c:0x6b:0x5f:0x46:0x31:0x38:0x30:0x42:0x34:0x36:0x31:0x44:0x32:0x43:0x35 fields: 021868 name(complete)=Expert&Milk_F180B461D2C5 021869 tx_pwr_lvl=4 Time to start further debugging 😊 Thank, Marc >Hello Marc, > >There is no additional configuration needed as long as you are using 1M PHY. >Would be good to get some logs and best would be to have btmon logs: >https://www.codecoup.pl/blog/support-for-btmon-in-mynewt/ > >Best >Łukasz >>On Mon, 8 Oct 2018 at 12:29, Marc BT <[email protected]> wrote: >> >> Hello all, >> >> I'm trying to configure two Nordic nRF52840-DK boards, one as advertiser >> (Extended Advertise), the other as scanner (Extended Scan). >> >> Compile settings (newt target amend ....): >> >> * BLE_EXT_ADV = 1 >> * BLE_EXT_ADV_MAX_SIZE = 700 >> >> I've used a TI kit to verify the existence of Extended Advertising. >> >> The board configured as Extended Advertiser works, the advertising packets >> can be seen on the TI board. >> The board configured as Extended Scanner doesn't return any advertising >> events. >> >> The HCI commands to setup the Extended Scan don't return any status error. >> >> Am I missing some compile switches ? >> >> Kind regards, >> Marc ________________________________ From: Marc BT Sent: Monday, October 8, 2018 12:13 PM To: [email protected] Subject: NimBLE Extended Scan Hello all, I'm trying to configure two Nordic nRF52840-DK boards, one as advertiser (Extended Advertise), the other as scanner (Extended Scan). Compile settings (newt target amend ....): * BLE_EXT_ADV = 1 * BLE_EXT_ADV_MAX_SIZE = 700 I've used a TI kit to verify the existence of Extended Advertising. The board configured as Extended Advertiser works, the advertising packets can be seen on the TI board. The board configured as Extended Scanner doesn't return any advertising events. The HCI commands to setup the Extended Scan don't return any status error. Am I missing some compile switches ? Kind regards, Marc