https://issues.apache.org/jira/browse/GEARPUMP-32?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15429979#comment-15429979
 ] 

ASF GitHub Bot commented on GEARPUMP-32:
----------------------------------------

Github user huafengw commented on a diff in the pull request:

    https://github.com/apache/incubator-gearpump/pull/67#discussion_r75612765
  
    --- Diff: 
examples/streaming/fsio/src/main/scala/org/apache/gearpump/streaming/examples/fsio/SeqFileStreamProducer.scala
 ---
    @@ -64,6 +65,6 @@ class SeqFileStreamProducer(taskContext: TaskContext, 
config: UserConfig)
     object SeqFileStreamProducer {
       def INPUT_PATH: String = "inputpath"
     
    -  val Start = Message("start")
    -  val Continue = Message("continue")
    +  val Start = Watermark(Instant.now)
    +  val Continue = Watermark(Instant.now)
    --- End diff --
    
    This Continue's timestamp will never move forward?


> Minimum clock of source Tasks maybe inaccurate
> ----------------------------------------------
>
>                 Key: GEARPUMP-32
>                 URL: https://issues.apache.org/jira/browse/GEARPUMP-32
>             Project: Apache Gearpump
>          Issue Type: Bug
>          Components: streaming
>    Affects Versions: 0.8.0
>            Reporter: Manu Zhang
>            Assignee: Manu Zhang
>             Fix For: 0.8.1
>
>
> Moved from [https://github.com/gearpump/gearpump/issues/1835] and reported by 
> [Zhu Yueqian|https://github.com/yueqianzhu]
> {quote}
> Source tasks have not any upstreamClocks. So, startClock is the minimum of 
> pending clocks when recover happen.
> eg below:
> source task1: timeStamp:15,not ACK, minClockValue maybe is 15(<= 15).
> source task2: timeStamp:10,ACKed, minClockValue maybe is Long.MaxValue
> when recover happen,startClock maybe is 15. where is the data between 10 to 
> 15 at task2?
> {quote}
> More context on this issue:
> In Gearpump, we maintain a global minimum clock tracked from a message's 
> timestamp across all tasks. It means messages with timestamp before this 
> clock have all been processed. An application will restart from this value on 
> failure, and thus at-least-once message delivery could be guaranteed. 
> The global minimum clock is the lower bound of all the Tasks' minimum clocks. 
> For a task, the minimum clock is the lower of 
> # upstream minimum clock
> # a. the minimum timestamp of unacked messages
>    b. Long.MaxValue if all messages have been acked.
>  
> Note that 2.b allows the global minimum clock to progress and it is almost 
> safe since the clock is also bounded by the upstream minimum clock. I said 
> "almost safe" because a source task has no upstream but we assume the 
> upstream minimum clock is Long.MaxValue. Thus, the scenario described by Zhu 
> Yueqian could happen and breaks at-least-once guarantee. 



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to