** Description changed: Cursor is not visible on screen connected via DisplayLink usb3 docking stations. It is working fine when the display is first time attached after login to Wayland Gnome session. - Then after logout it disappears. + Then after logout it disappears. On other hand cursor is working fine in XServer session. Steps to reproduce: 0. Install DisplayLink driver from https://www.displaylink.com/downloads/ubuntu 1. Boot with DisplayLink device unplugged 2. Plug the device on login screen. -> screen should be added and cursor should work on it. 3. Login to Gnome on Wayland (Ubuntu on wayland option) Expected: Cursor should is working on screen attached via DisplayLink device Got: Cursor is invisible - Reproduces with Ubuntu 20.04 Gnome/Wayland mutter version: mutter/focal 3.35.91-1ubuntu1 Reproducible on wide range of laptops, e.g XPS 13 9343 + + + The problem is most likely related to pre-existing /dev/driX devices, as when using the hotplug path everything is fine.
-- You received this bug notification because you are a member of Ubuntu Desktop Bugs, which is subscribed to mutter in Ubuntu. https://bugs.launchpad.net/bugs/1868702 Title: No cursor on DisplayLink screen after login to Wayland sesion in Ubuntu 20.04 To manage notifications about this bug go to: https://bugs.launchpad.net/ubuntu/+source/mutter/+bug/1868702/+subscriptions -- desktop-bugs mailing list [email protected] https://lists.ubuntu.com/mailman/listinfo/desktop-bugs