Felix Miata wrote on 12/6/19 11:22 AM:
> D. R. Evans composed on 2019-12-06 11:11 (UTC-0700):
> 
>> I have a buster system that is failing ever to reach a login prompt on the
>> console tty.
> 
>> The last message on the screen is:
>>   A start job is running for Hold until boot process finished up
>> followed by a timer that simply increases without end and says "no limit".
> 
>> How do I find out what is causing this?
> 
> After the last message appears, can you reach any of the other 5 vttys to find
> waiting logins? Right away? Only after some delay of many seconds, or more 
> than a
> minute?
> 

Nope, all just black.

But I could log in via ssh, and started backing out recent changes (I'm not
sure how long the problem had existed, as I don't normally look at the console
screen once X has started).

One of the changes was to switch to the Trinity desktop manager, and when I
reverted to using sddm, the problem went away.

I don't like sddm, but at least it allows the machine to reach a login screen,
so I'll forget about trying to use tdm on that machine, and assume that the
problem won't recur.

  Doc

-- 