On Tue, 2016-02-16 at 19:00 +0530, Ritesh Raj Sarraf wrote: > A couple days ago, I removed the smartmontools package. I suspected > that that may be causing trouble. For the last couple days, my klog > was > clean and I was tempted to report.
I installed smartmontools again, and ran some commands manually. And have some concerning report. And I think the reporting may be correct because where my HDD is located, temperature may be high. -- Ritesh Raj Sarraf RESEARCHUT - http://www.researchut.com "Necessity is the mother of invention."
smartctl 6.4 2014-10-07 r4002 [armv7l-linux-4.1.16-v7+] (local build) Copyright (C) 2002-14, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Barracuda Green (AF) Device Model: ST2000DL001-9VT156 Serial Number: 5YD0S8LQ LU WWN Device Id: 5 000c50 02ec00d59 Firmware Version: CC96 User Capacity: 2,000,398,934,016 bytes [2.00 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: 5900 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA8-ACS T13/1699-D revision 4 SATA Version is: SATA 3.0, 3.0 Gb/s (current: 1.5 Gb/s) Local Time is: Tue Feb 16 19:12:26 2016 IST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART Status command failed: scsi error medium or hardware error (serious) SMART overall-health self-assessment test result: PASSED Warning: This result is based on an Attribute check. See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 633) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 348) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x103b) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 117 099 006 Pre-fail Always - 552224292 3 Spin_Up_Time 0x0003 093 092 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 096 096 020 Old_age Always - 4253 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 078 060 030 Pre-fail Always - 62050510 9 Power_On_Hours 0x0032 088 088 000 Old_age Always - 10634 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 767 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 096 096 000 Old_age Always - 4 188 Command_Timeout 0x0032 100 099 000 Old_age Always - 25770197000 189 High_Fly_Writes 0x003a 094 094 000 Old_age Always - 6 190 Airflow_Temperature_Cel 0x0022 044 039 045 Old_age Always FAILING_NOW 56 (Min/Max 24/59 #2345) 191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 66 193 Load_Cycle_Count 0x0032 097 097 000 Old_age Always - 6983 194 Temperature_Celsius 0x0022 056 061 000 Old_age Always - 56 (0 19 0 0 0) 195 Hardware_ECC_Recovered 0x001a 123 099 000 Old_age Always - 552224292 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 8 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 8 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 5786 (251 0 0) 241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 2995904255 242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 1995971153 SMART Error Log Version: 1 ATA Error Count: 4 CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 4 occurred at disk power-on lifetime: 10633 hours (443 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 da 08 ff ff ff 4f 00 9d+22:59:30.548 READ DMA EXT 25 da 20 ff ff ff 4f 00 9d+22:59:30.524 READ DMA EXT 25 da 08 ff ff ff 4f 00 9d+22:59:27.183 READ DMA EXT 25 da 08 ff ff ff 4f 00 9d+22:59:23.907 READ DMA EXT 25 da 08 ff ff ff 4f 00 9d+22:59:23.906 READ DMA EXT Error 3 occurred at disk power-on lifetime: 10633 hours (443 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 da 08 ff ff ff 4f 00 9d+22:59:27.183 READ DMA EXT 25 da 08 ff ff ff 4f 00 9d+22:59:23.907 READ DMA EXT 25 da 08 ff ff ff 4f 00 9d+22:59:23.906 READ DMA EXT 25 da 08 ff ff ff 4f 00 9d+22:59:23.905 READ DMA EXT 25 da 08 ff ff ff 4f 00 9d+22:59:23.905 READ DMA EXT Error 2 occurred at disk power-on lifetime: 10633 hours (443 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 da 08 ff ff ff 4f 00 9d+22:59:23.907 READ DMA EXT 25 da 08 ff ff ff 4f 00 9d+22:59:23.906 READ DMA EXT 25 da 08 ff ff ff 4f 00 9d+22:59:23.905 READ DMA EXT 25 da 08 ff ff ff 4f 00 9d+22:59:23.905 READ DMA EXT 25 da 08 ff ff ff 4f 00 9d+22:59:23.905 READ DMA EXT Error 1 occurred at disk power-on lifetime: 10633 hours (443 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 ff ff ff 0f Error: UNC at LBA = 0x0fffffff = 268435455 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 25 da f0 ff ff ff 4f 00 9d+22:59:20.172 READ DMA EXT 25 da f0 ff ff ff 4f 00 9d+22:59:20.168 READ DMA EXT 25 da f0 ff ff ff 4f 00 9d+22:59:20.164 READ DMA EXT 35 da 40 ff ff ff 4f 00 9d+22:59:20.162 WRITE DMA EXT 35 da f0 ff ff ff 4f 00 9d+22:59:20.158 WRITE DMA EXT SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 8279 - # 2 Short offline Aborted by host 50% 8279 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
signature.asc
Description: This is a digitally signed message part