I had the same problem this morning with testing.
My fix was to simply to back out the new libkdecorations2-5v5 :
debsnap -d . --binary -a amd64 libkdecorations2-5v5 4:5.17.5-2
sudo dpkg -i libkdecorations2-5v5_5.17.5-2_amd64.deb
dpkg --get-selections \* | grep -P '^libkdecorations2-5v5' \
| sed -e 's/install/hold/' > libkdecorations2-5v5.hold
sudo dpkg --set-selections < libkdecorations2-5v5.hold
That was good enough to get things working for today!
Andy.
On Monday, 9 November 2020 07:27:15 GMT Thom Castermans wrote:
> Hi Héctor,
>
> Not sure if it was the same problem, but when I logged in today I did
> not have window decorations and was generally missing some kwin
> functionality. Turned out I could not start kwin due to a missing
> symbol. Running `apt full-upgrade` resolved the issue by installing a
> lot of kf5* packages. I thought apt would protect me from this, but it
> remains unstable/testing for a reason!
>
> Hope that helps, best regards,
> Thom
>
> Op ma 9 nov. 2020 om 07:54 schreef Héctor Sales Llamas
<[email protected]>:
> > Hello, today some plasma 5.19.5-3 packages have entered testing . After
> > reboot and logging into the system, plasma is partially broken. I
> > suspect it has to do with the partial plasma upgrade 5.19.x. How can i
> > fix this ?. Why did these packages go into testing partially ?
> >
> > Start-Date: 2020-11-09 05:23:55
> > Commandline: apt upgrade
> > Requested-By: hector (1000)
> > Install: libkdecorations2private7:amd64 (4:5.19.5-3, automatic)
> > Upgrade: openssl:amd64 (1.1.1g-1, 1.1.1h-1), libkdecorations2-5v5:amd64
> > (4:5.17.5-2, 4:5.19.5-3), libxnvctrl0:amd64 (450.66-1, 450.80.02-1),
> > libkf5screen-bin:amd64 (4:5.17.5-3, 4:5.19.5-3), libkf5screen7:amd64
> > (4:5.17.5-3, 4:5.19.5-3), libssl-dev:amd64 (1.1.1g-1, 1.1.1h-1),
> > libssl1.1:amd64 (1.1.1g-1, 1.1.1h-1), libssl1.1:i386 (1.1.1g-1,
> > 1.1.1h-1), nvidia-settings:amd64 (450.66-1, 450.80.02-1) End-Date:
> > 2020-11-09 05:24:18
This email and any attachments are intended solely for the use of the named
recipients. If you are not the intended recipient you must not use, disclose,
copy or distribute this email or any of its attachments and should notify the
sender immediately and delete this email from your system. UK Research and
Innovation (UKRI) has taken every reasonable precaution to minimise risk of
this email or any attachments containing viruses or malware but the recipient
should carry out its own virus and malware checks before opening the
attachments. UKRI does not accept any liability for any losses or damages which
the recipient may sustain due to presence of any viruses. Opinions, conclusions
or other information in this message and attachments that are not related
directly to UKRI business are solely those of the author and do not represent
the views of UKRI.