Package: lm-sensors Version: 1:3.0.2-1+b2 Severity: normal
Config is wrong on (old) motherboard Tyan Tiger MPX (S2466N-4M). For example, temperature readings. vinc...@cocotte-et-le-loup:~$ sensors w83782d-i2c-0-2d Adapter: SMBus AMD768 adapter at 80e0 VCore 1: +1.47 V (min = +0.00 V, max = +4.08 V) VCore 2: +1.54 V (min = +0.00 V, max = +4.08 V) +3.3V: +1.54 V (min = +3.14 V, max = +3.47 V) ALARM +5V: +4.73 V (min = +4.76 V, max = +5.24 V) ALARM +12V: +4.68 V (min = +0.00 V, max = +7.78 V) -12V: -2.16 V (min = -14.91 V, max = -14.91 V) ALARM -5V: +2.59 V (min = +1.23 V, max = +2.19 V) ALARM V5SB: +4.19 V (min = +0.00 V, max = +0.00 V) ALARM VBat: +4.08 V (min = +2.64 V, max = +3.95 V) ALARM fan1: 112500 RPM (min = 21093 RPM, div = 2) fan2: 0 RPM (min = -1 RPM, div = 2) ALARM fan3: 225000 RPM (min = 42187 RPM, div = 2) temp1: +80.0°C (high = +0.0°C, hyst = +0.0°C) ALARM sensor = thermistor temp2: +79.0°C (high = +80.0°C, hyst = +75.0°C) sensor = thermistor temp3: +80.0°C (high = +80.0°C, hyst = +75.0°C) sensor = thermistor cpu0_vid: +1.500 V beep_enable:enabled w83627hf-isa-0c00 Adapter: ISA adapter VCore 1: +1.46 V (min = +1.42 V, max = +1.57 V) VCore 2: +1.47 V (min = +1.42 V, max = +1.57 V) +3.3V: +3.30 V (min = +3.14 V, max = +3.47 V) +5V: +4.89 V (min = +0.75 V, max = +0.00 V) ALARM +12V: +9.18 V (min = +10.46 V, max = +8.57 V) ALARM -12V: -12.28 V (min = -13.18 V, max = -10.80 V) -5V: +0.03 V (min = -6.10 V, max = -7.71 V) ALARM V5SB: +5.48 V (min = +0.00 V, max = +3.49 V) ALARM VBat: +3.25 V (min = +2.13 V, max = +0.26 V) ALARM fan1: 0 RPM (min = 84375 RPM, div = 2) ALARM fan2: 0 RPM (min = 84375 RPM, div = 2) ALARM fan3: 0 RPM (min = 168750 RPM, div = 2) ALARM temp1: +77.0°C (high = +64.0°C, hyst = +70.0°C) ALARM sensor = thermistor temp2: +79.0°C (high = +80.0°C, hyst = +75.0°C) sensor = thermistor temp3: +77.0°C (high = +80.0°C, hyst = +75.0°C) sensor = thermistor cpu0_vid: +1.500 V beep_enable:disabled (Motherboard infos: http://www.tyan.com/archive/products/html/tigermpx.html) -- System Information: Debian Release: 5.0.4 APT prefers stable APT policy: (900, 'stable') Architecture: i386 (i686) Kernel: Linux 2.6.30-bpo.2-686 (SMP w/1 CPU core) Locale: LANG=en_US.UTF-8, LC_CTYPE=en_US.UTF-8 (charmap=UTF-8) Shell: /bin/sh linked to /bin/bash Versions of packages lm-sensors depends on: ii libc6 2.10.2-6 Embedded GNU C Library: Shared lib ii libsensors4 1:3.0.2-1+b2 library to read temperature/voltag ii perl 5.10.0-19lenny2 Larry Wall's Practical Extraction ii sed 4.1.5-6 The GNU sed stream editor lm-sensors recommends no packages. Versions of packages lm-sensors suggests: ii i2c-tools 3.0.1-1 heterogeneous set of I2C tools for ii read-edid 1.4.1-2.1 hardware information-gathering too pn sensord <none> (no description available) -- no debconf information -- To UNSUBSCRIBE, email to debian-bugs-dist-requ...@lists.debian.org with a subject of "unsubscribe". Trouble? Contact listmas...@lists.debian.org