Package: smartmontools Version: 5.39.1+svn3060-1 Severity: minor In manual of smartctl: If the GLTSD bit is set then ´smartctl -a´ will issue a warning.
But if SMART attribute autosave if disabled for SATA drive, no any warning issued in -a or -x output. Steps to reproduce: smartctl -S on /dev/sda smartctl -a /dev/sda >1 smartctl -S off /dv/sda smartctl -a /dev/hsda >2 diff 1 2 13c13 < Local Time is: Mon Feb 22 07:03:12 2010 MSK --- > Local Time is: Mon Feb 22 07:03:21 2010 MSK ====== begin of -x output ==== Data about drive: === START OF INFORMATION SECTION === Model Family: Hitachi Deskstar 7K80 series Device Model: HDS728080PLA380 Serial Number: PFDB32E8U1NLYM Firmware Version: PF2OA6EA User Capacity: 82Â 348Â 277Â 760 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: ATA/ATAPI-7 T13 1532D revision 1 Local Time is: Mon Feb 22 07:11:57 2010 MSK SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 36) The self-test routine was interrupted by the host with a hard or soft reset. Total time to complete Offline data collection: (1828) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 31) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0 2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline - 0 3 Spin_Up_Time 0x0007 105 105 024 Pre-fail Always - 195 (Average 184) 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 92 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail Offline - 0 9 Power_On_Hours 0x0012 099 099 000 Old_age Always - 9386 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 92 192 Power-Off_Retract_Count 0x0032 100 100 050 Old_age Always - 445 193 Load_Cycle_Count 0x0012 100 100 050 Old_age Always - 445 194 Temperature_Celsius 0x0002 137 137 000 Old_age Always - 40 (Lifetime Min/Max 17/47) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 253 000 Old_age Always - 0 General Purpose Logging (GPL) feature set supported General Purpose Log Directory Version 1 SMART Log Directory Version 1 [multi-sector log support] GP/S Log at address 0x00 has 1 sectors [Log Directory] SMART Log at address 0x01 has 1 sectors [Summary SMART error log] GP Log at address 0x03 has 1 sectors [Ext. Comprehensive SMART error log] SMART Log at address 0x06 has 1 sectors [SMART self-test log] GP Log at address 0x07 has 1 sectors [Extended self-test log] SMART Log at address 0x09 has 1 sectors [Selective self-test log] GP Log at address 0x10 has 1 sectors [NCQ Command Error] GP Log at address 0x20 has 1 sectors [Streaming performance log] GP Log at address 0x21 has 1 sectors [Write stream error log] GP Log at address 0x22 has 1 sectors [Read stream error log] GP/S Log at address 0x80 has 16 sectors [Host vendor specific log] GP/S Log at address 0x81 has 16 sectors [Host vendor specific log] GP/S Log at address 0x82 has 16 sectors [Host vendor specific log] GP/S Log at address 0x83 has 16 sectors [Host vendor specific log] GP/S Log at address 0x84 has 16 sectors [Host vendor specific log] GP/S Log at address 0x85 has 16 sectors [Host vendor specific log] GP/S Log at address 0x86 has 16 sectors [Host vendor specific log] GP/S Log at address 0x87 has 16 sectors [Host vendor specific log] GP/S Log at address 0x88 has 16 sectors [Host vendor specific log] GP/S Log at address 0x89 has 16 sectors [Host vendor specific log] GP/S Log at address 0x8a has 16 sectors [Host vendor specific log] GP/S Log at address 0x8b has 16 sectors [Host vendor specific log] GP/S Log at address 0x8c has 16 sectors [Host vendor specific log] GP/S Log at address 0x8d has 16 sectors [Host vendor specific log] GP/S Log at address 0x8e has 16 sectors [Host vendor specific log] GP/S Log at address 0x8f has 16 sectors [Host vendor specific log] GP/S Log at address 0x90 has 16 sectors [Host vendor specific log] GP/S Log at address 0x91 has 16 sectors [Host vendor specific log] GP/S Log at address 0x92 has 16 sectors [Host vendor specific log] GP/S Log at address 0x93 has 16 sectors [Host vendor specific log] GP/S Log at address 0x94 has 16 sectors [Host vendor specific log] GP/S Log at address 0x95 has 16 sectors [Host vendor specific log] GP/S Log at address 0x96 has 16 sectors [Host vendor specific log] GP/S Log at address 0x97 has 16 sectors [Host vendor specific log] GP/S Log at address 0x98 has 16 sectors [Host vendor specific log] GP/S Log at address 0x99 has 16 sectors [Host vendor specific log] GP/S Log at address 0x9a has 16 sectors [Host vendor specific log] GP/S Log at address 0x9b has 16 sectors [Host vendor specific log] GP/S Log at address 0x9c has 16 sectors [Host vendor specific log] GP/S Log at address 0x9d has 16 sectors [Host vendor specific log] GP/S Log at address 0x9e has 16 sectors [Host vendor specific log] GP/S Log at address 0x9f has 16 sectors [Host vendor specific log] SMART Extended Comprehensive Error Log Version: 1 (1 sectors) Device Error Count: 5 (device log contains only the most recent 4 errors) CR = Command Register FEATR = Features Register COUNT = Count (was: Sector Count) Register LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8 LH = LBA High (was: Cylinder High) Register ] LBA LM = LBA Mid (was: Cylinder Low) Register ] Register LL = LBA Low (was: Sector Number) Register ] DV = Device (was: Device/Head) Register DC = Device Control Register ER = Error register ST = Status register Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 5 [0] occurred at disk power-on lifetime: 9385 hours (391 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 51 00 00 00 00 00 c2 4f 09 00 00 Error: IDNF Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- b0 00 d6 00 01 00 00 00 c2 4f 09 00 08 21d+07:57:29.200 SMART WRITE LOG b0 00 d5 00 01 00 00 00 c2 4f 09 00 08 21d+07:57:29.100 SMART READ LOG b0 00 d1 00 01 00 00 00 c2 4f 01 00 08 21d+07:57:29.000 SMART READ ATTRIBUTE THRESHOLDS [OBS-4] b0 00 d0 00 01 00 00 00 c2 4f 00 00 08 21d+07:57:29.000 SMART READ DATA b0 00 da 00 00 00 00 00 c2 4f 00 00 08 21d+07:57:28.900 SMART RETURN STATUS Error 4 [3] occurred at disk power-on lifetime: 9385 hours (391 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 51 00 00 00 00 00 c2 4f 09 00 00 Error: IDNF Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- b0 00 d6 00 01 00 00 00 c2 4f 09 00 08 21d+07:43:58.200 SMART WRITE LOG b0 00 d5 00 01 00 00 00 c2 4f 09 00 08 21d+07:43:58.100 SMART READ LOG b0 00 d1 00 01 00 00 00 c2 4f 01 00 08 21d+07:43:58.000 SMART READ ATTRIBUTE THRESHOLDS [OBS-4] b0 00 d0 00 01 00 00 00 c2 4f 00 00 08 21d+07:43:57.900 SMART READ DATA b0 00 da 00 00 00 00 00 c2 4f 00 00 08 21d+07:43:57.900 SMART RETURN STATUS Error 3 [2] occurred at disk power-on lifetime: 9385 hours (391 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 51 00 00 00 00 00 c2 4f 09 00 00 Error: IDNF Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- b0 00 d6 00 01 00 00 00 c2 4f 09 00 08 21d+07:43:54.100 SMART WRITE LOG b0 00 d5 00 01 00 00 00 c2 4f 09 00 08 21d+07:43:54.000 SMART READ LOG 61 00 08 00 00 00 00 00 7a f6 8e 40 08 21d+07:43:54.000 WRITE FPDMA QUEUED b0 00 d1 00 01 00 00 00 c2 4f 01 00 08 21d+07:43:53.900 SMART READ ATTRIBUTE THRESHOLDS [OBS-4] 61 00 30 00 00 00 00 00 7a f6 5e 40 08 21d+07:43:53.900 WRITE FPDMA QUEUED Error 2 [1] occurred at disk power-on lifetime: 9385 hours (391 days + 1 hours) When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were: ER -- ST COUNT LBA_48 LH LM LL DV DC -- -- -- == -- == == == -- -- -- -- -- 10 -- 51 00 00 00 00 00 c2 4f 09 00 00 Error: IDNF Commands leading to the command that caused the error were: CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name -- == -- == -- == == == -- -- -- -- -- --------------- -------------------- b0 00 d6 00 01 00 00 00 c2 4f 09 00 08 21d+07:43:47.800 SMART WRITE LOG b0 00 d5 00 01 00 00 00 c2 4f 09 00 08 21d+07:43:47.700 SMART READ LOG b0 00 d1 00 01 00 00 00 c2 4f 01 00 08 21d+07:43:47.600 SMART READ ATTRIBUTE THRESHOLDS [OBS-4] b0 00 d0 00 01 00 00 00 c2 4f 00 00 08 21d+07:43:47.500 SMART READ DATA b0 00 da 00 00 00 00 00 c2 4f 00 00 08 21d+07:43:47.400 SMART RETURN STATUS SMART Extended Self-test Log Version: 1 (1 sectors) Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short captive Interrupted (host reset) 40% 9386 - # 2 Short captive Interrupted (host reset) 40% 9385 - # 3 Extended offline Completed without error 00% 9384 - # 4 Extended offline Completed without error 00% 8599 - # 5 Extended offline Completed without error 00% 8512 - # 6 Extended offline Completed without error 00% 3269 - # 7 Extended offline Completed without error 00% 2885 - # 8 Extended offline Completed without error 00% 2883 - Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum. SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. Warning: device does not support SCT Commands SATA Phy Event Counters (GP Log 0x11) not supported ==== end of -x output ===== -- Package-specific info: Output of /usr/share/bug/smartmontools: # CONFIG_IDE_TASK_IOCTL is not set -- System Information: Debian Release: 5.0.4 APT prefers stable APT policy: (990, 'stable'), (500, 'unstable') Architecture: amd64 (x86_64) Kernel: Linux 2.6.26-2-amd64 (SMP w/4 CPU cores) Locale: LANG=C, LC_CTYPE=C (charmap=ANSI_X3.4-1968) Shell: /bin/sh linked to /bin/bash Versions of packages smartmontools depends on: ii debianutils 2.30 Miscellaneous utilities specific t ii libc6 2.10.2-6 Embedded GNU C Library: Shared lib ii libcap-ng0 0.6.2-4+b1 An alternate posix capabilities li ii libgcc1 1:4.4.3-2 GCC support library ii libselinux1 2.0.89-4 SELinux runtime shared libraries ii libstdc++6 4.4.3-2 The GNU Standard C++ Library v3 ii lsb-base 3.2-20 Linux Standard Base 3.2 init scrip Versions of packages smartmontools recommends: ii mailutils [mailx] 1:1.2+dfsg1-4 GNU mailutils utilities for handli Versions of packages smartmontools suggests: pn gsmartcontrol <none> (no description available) pn powersaved <none> (no description available) ii smart-notifier 0.28-1.1 graphical hard disk health status -- debconf-show failed -- To UNSUBSCRIBE, email to debian-bugs-dist-requ...@lists.debian.org with a subject of "unsubscribe". Trouble? Contact listmas...@lists.debian.org