reassign 307089 libsane-extras
retitle 307089: libsane-extras: [epkowa] uses a resolution range when scanner 
doesn't support it
thanks

Mark Nipper <[EMAIL PROTECTED]> wrote:

Hi Mark, David,

> However, it still segfaults when trying to move the resolution
> slider.  Attached the output using SANE_DEBUG_EPKOWA=255.

This problem has been diagnosed as a bug in the epkowa backend, which
always reports a resolution range even when the scanner supports only
a fixed list of resolutions.

This only happens for a precise type of scanners.

No ETA for the fix, but it shouldn't take long, hopefully.

Could you have a look to the advanced options, and see if you have an
option like "show a list of resolutions" ? I saw something like that
in the advanced options of my 2480, maybe it could be used as a
workaround until the fix.



As for the original bug report, the bug seen with the epson backend is
just not possible; the epson backend always reports a list of
resolutions.

JB.

-- 
 Julien BLACHE <[EMAIL PROTECTED]>  |  Debian, because code matters more 
 Debian & GNU/Linux Developer        |       <http://www.debian.org>
 Public key available on <http://www.jblache.org> - KeyID: F5D6 5169 
 GPG Fingerprint : 935A 79F1 C8B3 3521 FD62 7CC7 CD61 4FD7 F5D6 5169 


-- 
To UNSUBSCRIBE, email to [EMAIL PROTECTED]
with a subject of "unsubscribe". Trouble? Contact [EMAIL PROTECTED]