> What are you expecting? Ah..I see what happened. In Linux kernel the support for my chipset, SCH3114, is contained inside dme1737 module. So the module dme1737 has to be loaded to get output from sensors. Since there is no specific settings for SCH311X in sensors3.conf I thought may be the settings of dme1737 in sensors3.conf should work because that is the required module. However, I got it working by adding the following files to my sensors3.conf file. chip "sch311x-isa-*" # Temperature inputs label temp1 "CPU Temp" label temp2 "M/B Temp" label temp3 ""Unknown" or better just adding "sch311x-isa-*" after chip "dme1737-*" also works fine. Thank you for the hint. Kushal Koolwal I do blog at http://blogs.koolwal.net/ _________________________________________________________________ HotmailĀ® is up to 70% faster. Now good news travels really fast. http://windowslive.com/online/hotmail?ocid=TXT_TAGLM_WL_HM_70faster_032009
-- To UNSUBSCRIBE, email to debian-bugs-dist-requ...@lists.debian.org with a subject of "unsubscribe". Trouble? Contact listmas...@lists.debian.org