Hi, On Tue, 13 Dec 2016 00:30:17 +0100 (CET) ydir...@free.fr wrote: > Package: edid-decode > Version: 0.1~git20140128.afcf2a2e-1 > > The spec states that only when the "Alphanumeric Data String Descriptor > Definition" is less > than 13 bytes, should it be followed by 0x0A and further padded with 0x20. > > Thus, a 13-byte string without a 0x0A is valid, but edid-decode rejects it. > > Note that other fields have the same description, eg. "Display Product Serial > Number Descriptor Definition"
I’m uploading a more recent snapshot, can you please test it when it’s available? Thanks. -- Cheers, Andrej