control: forwarded -1 https://github.com/ibus/ibus/issues/1847 control: outlook -1 workaround: pkill -u $USER ibus-daemon; IBUS_ENABLE_SYNC_MODE=0 ibus-daemon --xim --daemonize
Hello Osamu, On Tue, Aug 29 2017, Osamu Aoki wrote: > Yes. But if ibus related libraries are available it uses such library > to pass input instead of using xim. If ibus related libraries aren't > available, ibus use xim to pass keyboard input. Okay. I finally found a workaround: pkill -u $USER ibus-daemon; IBUS_ENABLE_SYNC_MODE=0 ibus-daemon --xim --daemonize -- Sean Whitton