Package: thinkfan
Version: 0.8.1-1
Severity: normal

Dear Maintainer,

After installation the /etc/thinkfan.conf lacks a line that activates the 
full-speed level of the fan.

I copied the line from the german thinkwiki:
(127,   75,     32767) # Wichtig: diese Zeile (127 = "disengaged" d.h. 
ungeregelt) sorgt für volle Lüfterdrehzahl

http://thinkwiki.de/Thinkfan#Temperaturschwellen_konfigurieren

Now the fan reaches a speed over 6000 when the cpu is getting hot.

Greets
Jens Korte

-- System Information:
Debian Release: 7.8
  APT prefers oldstable
  APT policy: (1001, 'oldstable'), (500, 'oldstable-updates'), (500, 
'oldstable-proposed-updates')
Architecture: i386 (i686)

Kernel: Linux 3.16.0-0.bpo.4-586
Locale: LANG=de_DE.UTF-8, LC_CTYPE=de_DE.UTF-8 (charmap=UTF-8)
Shell: /bin/sh linked to /bin/dash

Versions of packages thinkfan depends on:
ii  libc6  2.13-38+deb7u8

thinkfan recommends no packages.

thinkfan suggests no packages.

-- Configuration Files:
/etc/default/thinkfan changed:
START=yes
DAEMON_ARGS="-q"

/etc/thinkfan.conf changed:
(0,     0,      42)
(1,     38,     53)
(2,     50,     61)
(3,     52,     63)
(4,     56,     65)
(5,     59,     66)
(7,     63,     73)
(127,   70,     32767) # Wichtig: diese Zeile (127 = "disengaged" d.h. 
ungeregelt) sorgt für volle Lüfterdrehzahl


-- no debconf information

Reply via email to