Package: thinkfan Version: 0.8.1-1 Severity: normal Dear Maintainer,
After installation the /etc/thinkfan.conf lacks a line that activates the full-speed level of the fan. I copied the line from the german thinkwiki: (127, 75, 32767) # Wichtig: diese Zeile (127 = "disengaged" d.h. ungeregelt) sorgt für volle Lüfterdrehzahl http://thinkwiki.de/Thinkfan#Temperaturschwellen_konfigurieren Now the fan reaches a speed over 6000 when the cpu is getting hot. Greets Jens Korte -- System Information: Debian Release: 7.8 APT prefers oldstable APT policy: (1001, 'oldstable'), (500, 'oldstable-updates'), (500, 'oldstable-proposed-updates') Architecture: i386 (i686) Kernel: Linux 3.16.0-0.bpo.4-586 Locale: LANG=de_DE.UTF-8, LC_CTYPE=de_DE.UTF-8 (charmap=UTF-8) Shell: /bin/sh linked to /bin/dash Versions of packages thinkfan depends on: ii libc6 2.13-38+deb7u8 thinkfan recommends no packages. thinkfan suggests no packages. -- Configuration Files: /etc/default/thinkfan changed: START=yes DAEMON_ARGS="-q" /etc/thinkfan.conf changed: (0, 0, 42) (1, 38, 53) (2, 50, 61) (3, 52, 63) (4, 56, 65) (5, 59, 66) (7, 63, 73) (127, 70, 32767) # Wichtig: diese Zeile (127 = "disengaged" d.h. ungeregelt) sorgt für volle Lüfterdrehzahl -- no debconf information