On sam., 2014-10-04 at 14:07 +0100, Chris Bainbridge wrote: > The problem happens when the laptop battery is not recognised so the > Linux kernel instead use the hex string ID of the manufacturer and > model. These strings are 31 characters each. On the "Device" tab the > left side contains a 1 line string of the full "$manufacturer $model" > string, which for an unrecognised battery will be 63 characters long. > The container expands to hold this and keep it on a single line, which > causes the whole window to increase in size, which in turn expands all > of the tabs to fit. > > The following patch will fix the width of the devices column at 200px > to stop it from being expanded: > > diff --git a/settings/xfpm-settings.c b/settings/xfpm-settings.c > index d736cd4..f27fa70 100644 > --- a/settings/xfpm-settings.c > +++ b/settings/xfpm-settings.c > @@ -2093,6 +2093,8 @@ xfpm_settings_dialog_new (XfconfChannel > *channel, gboolean auth_suspend, > > gtk_tree_view_set_rules_hint (GTK_TREE_VIEW (sideview),TRUE); > col = gtk_tree_view_column_new (); > + gtk_tree_view_column_set_sizing(col, GTK_TREE_VIEW_COLUMN_FIXED); > + gtk_tree_view_column_set_fixed_width(col, 200); > > renderer = gtk_cell_renderer_pixbuf_new (); >
Can you provide the information requested at https://bugzilla.xfce.org/show_bug.cgi?id=11217#c1 ? Regards, -- Yves-Alexis
signature.asc
Description: This is a digitally signed message part