Package: acpitool Version: 0.5.1-3 Severity: minor --- Please enter the report below this line. --- Hello,
I noticed battery capacity unit inconsistency between acpi (mAh) and acpitool (mA)
$ acpi -bi Battery 0: Charging, 79%, 962:00:00 until charged Battery 0: design capacity 5856 mAh, last full capacity 4785 mAh = 81% $ acpitool -B Battery #1 : present Remaining capacity : unknown, 79.90%, 962:00:00 Design capacity : 5856 mA Last full capacity : 4785 mA, 81.71% of design capacity Capacity loss : 18.29% Present rate : 1 mA Charging state : Charging Battery type : Li-ion Model number : Dell Serial number : 2372 $ acpi -v acpi 1.6 $ acpitool -V AcpiTool v0.5.1, released 13-Aug-2009 Thanks, Milosz --- System information. --- Architecture: amd64 Kernel: Linux 3.2.0-4-amd64 Debian Release: 7.0 500 testing security.debian.org 500 testing ftp.task.gda.pl 500 stable dl.google.com --- Package information. --- Depends (Version) | Installed ===========================-+-============= libc6 (>= 2.2.5) | 2.13-37 libgcc1 (>= 1:4.1.1) | 1:4.7.2-4 libstdc++6 (>= 4.4.0) | 4.7.2-4 Recommends (Version) | Installed =========================-+-=========== acpid | 1:2.0.16-1 Package's Suggests field is empty. -- To UNSUBSCRIBE, email to debian-bugs-dist-requ...@lists.debian.org with a subject of "unsubscribe". Trouble? Contact listmas...@lists.debian.org