On Mon, Oct 01, 2012 at 10:32:36AM +0200, Pierre Colombier wrote:
> When the "50 minute shift" occurs. It occurs simultaneously on all domU
> and dom0.
> on all domU and dom0, the syslog says
> Clocksource tsc unstable (delta = -2999660303146 ns)  (or something very
> near 3000 seconds)

The TSC is unstable for whatever reason.

Please provide complete kernel (dmesg) and hypervisor logs (xm dmesg).
Please check if the machines runs the latest firmware.
Does it also happen with the testing versions of either Xen or Linux?

Bastian

-- 
To live is always desirable.
                -- Eleen the Capellan, "Friday's Child", stardate 3498.9


-- 
To UNSUBSCRIBE, email to debian-bugs-dist-requ...@lists.debian.org
with a subject of "unsubscribe". Trouble? Contact listmas...@lists.debian.org

Reply via email to