Your message dated Sat, 12 Oct 2024 15:18:33 +0200
with message-id <zwp3kvd04_lqg...@aurel32.net>
and subject line Re: Bug#1082934: temperatures: jc42 high and crit is 0
has caused the Debian Bug report #1082934,
regarding temperatures: jc42 high and crit is 0
to be marked as done.

This means that you claim that the problem has been dealt with.
If this is not the case it is now your responsibility to reopen the
Bug report if necessary, and/or fix the problem forthwith.

(NB: If you are a system administrator and have no idea what this
message is talking about, this may indicate a serious mail system
misconfiguration somewhere. Please contact ow...@bugs.debian.org
immediately.)


-- 
1082934: https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=1082934
Debian Bug Tracking System
Contact ow...@bugs.debian.org with problems
--- Begin Message ---
Package: lm-sensors
Version: 1:3.6.0-7.1
Severity: normal
X-Debbugs-Cc: jens...@gmx.de

Dear Maintainer,

* when executing sensors jc42-devices report low, how and crit = +0.0°C
* in my example i have the following jc42-devices:
** jc42-i2c-1-19
** jc42-i2c-1-1b
* this leads to Alarms when monitoring the system e.g. with psutil 
* i expect sensors to report either no low/high/crit values or plausible values

-- System Information:
Debian Release: 12.7
  APT prefers stable-updates
  APT policy: (500, 'stable-updates'), (500, 'stable-security'), (500, 'stable')
Architecture: amd64 (x86_64)

Kernel: Linux 6.8.12-1-pve (SMP w/4 CPU threads; PREEMPT)
Kernel taint flags: TAINT_PROPRIETARY_MODULE, TAINT_OOT_MODULE
Locale: LANG=en_US.UTF-8, LC_CTYPE=en_US.UTF-8 (charmap=UTF-8), LANGUAGE not set
Shell: /bin/sh linked to /usr/bin/dash
Init: systemd (via /run/systemd/system)
LSM: AppArmor: enabled

Versions of packages lm-sensors depends on:
ii  libc6                      2.36-9+deb12u8
ii  libsensors5                1:3.6.0-7.1
ii  lsb-base                   11.6
ii  perl                       5.36.0-7+deb12u1
ii  sed                        4.9-1
ii  sysvinit-utils [lsb-base]  3.06-4

lm-sensors recommends no packages.

Versions of packages lm-sensors suggests:
pn  fancontrol  <none>
pn  i2c-tools   <none>
pn  read-edid   <none>

-- no debconf information

--- End Message ---
--- Begin Message ---
On 2024-09-28 18:21, Aurelien Jarno wrote:
> Hi,
> 
> On 2024-09-28 17:59, Jens Metschkoll wrote:
> > Package: lm-sensors
> > Version: 1:3.6.0-7.1
> > Severity: normal
> > X-Debbugs-Cc: jens...@gmx.de
> > 
> > Dear Maintainer,
> > 
> > * when executing sensors jc42-devices report low, how and crit = +0.0°C
> > * in my example i have the following jc42-devices:
> > ** jc42-i2c-1-19
> > ** jc42-i2c-1-1b
> > * this leads to Alarms when monitoring the system e.g. with psutil 
> > * i expect sensors to report either no low/high/crit values or plausible 
> > values
> 
> Thanks for your bug report. lm-sensors is just an interface to the
> values provided by the kernel. Therefore in order to debug things
> further, could you please send me the full output of the following commands:
> 
> - sensors
> - grep . /sys/class/hwmon/hwmon*/temp*

As explained offline, the value returned by lm-sensors are consistent
with the values provided by the kernel, therefore this is not an issue
from lm-sensors. I am therefore closing the bug.

Regards
Aurelien

-- 
Aurelien Jarno                          GPG: 4096R/1DDD8C9B
aurel...@aurel32.net                     http://aurel32.net