Your message dated Sat, 14 Jan 2023 15:05:26 +0100
with message-id <[email protected]>
and subject line Re: Bug#1025902: tlp: Battery charge thresholds are ignored
has caused the Debian Bug report #1025902,
regarding tlp: Battery charge thresholds are ignored
to be marked as done.
This means that you claim that the problem has been dealt with.
If this is not the case it is now your responsibility to reopen the
Bug report if necessary, and/or fix the problem forthwith.
(NB: If you are a system administrator and have no idea what this
message is talking about, this may indicate a serious mail system
misconfiguration somewhere. Please contact [email protected]
immediately.)
--
1025902: https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=1025902
Debian Bug Tracking System
Contact [email protected] with problems
--- Begin Message ---
Package: tlp
Version: 1.5.0-1
Severity: normal
X-Debbugs-Cc: [email protected]
Dear Maintainer,
TLP does not set the battery charge threshold configured in the TLP
configuration file.
Specifically, the configuration file (attached) aims to set the battery charge
thresholds to something like 75%. However, the battery is charged to 100%. The
output of `tlp-stat -b` is
```
# tlp-stat -b
--- TLP 1.5.0 --------------------------------------------
+++ Battery Care
Plugin: thinkpad
Supported features: charge thresholds, recalibration
Driver usage:
* natacpi (thinkpad_acpi) = active (charge thresholds, recalibration)
Parameter value ranges:
* START_CHARGE_THRESH_BAT0/1: 0(off)..96(default)..99
* STOP_CHARGE_THRESH_BAT0/1: 1..100(default)
+++ ThinkPad Battery Status: BAT0 (Main / Internal)
/sys/class/power_supply/BAT0/manufacturer = SMP
/sys/class/power_supply/BAT0/model_name = 5B10W51864
/sys/class/power_supply/BAT0/cycle_count = 7
/sys/class/power_supply/BAT0/energy_full_design = 52500 [mWh]
/sys/class/power_supply/BAT0/energy_full = 52500 [mWh]
/sys/class/power_supply/BAT0/energy_now = 37640 [mWh]
/sys/class/power_supply/BAT0/power_now = 4902 [mW]
/sys/class/power_supply/BAT0/status = Discharging
/sys/class/power_supply/BAT0/charge_control_start_threshold = 0 [%]
/sys/class/power_supply/BAT0/charge_control_end_threshold = 100 [%]
/sys/class/power_supply/BAT0/charge_behaviour = [auto] inhibit-
charge force-discharge
Charge = 71.7 [%]
Capacity = 100.0 [%]
```
Rebooting does not change the output, or the charging behaviour.
-- System Information:
Debian Release: bookworm/sid
APT prefers unstable
APT policy: (500, 'unstable')
Architecture: amd64 (x86_64)
Kernel: Linux 6.0.0-5-amd64 (SMP w/12 CPU threads; PREEMPT)
Locale: LANG=en_GB.UTF-8, LC_CTYPE=en_GB.UTF-8 (charmap=UTF-8),
LANGUAGE=en_GB:en
Shell: /bin/sh linked to /usr/bin/dash
Init: systemd (via /run/systemd/system)
LSM: AppArmor: enabled
Versions of packages tlp depends on:
ii hdparm 9.65+ds-1
ii iw 5.19-1
ii pciutils 1:3.9.0-2
ii rfkill 2.38.1-4
ii usbutils 1:014-1
Versions of packages tlp recommends:
ii ethtool 1:6.0-1
ii tlp-rdw 1.5.0-1
Versions of packages tlp suggests:
pn acpi-call-dkms <none>
pn linux-cpupower <none>
pn smartmontools <none>
ii tp-smapi-dkms 0.43-1
-- Configuration Files:
/etc/tlp.conf changed:
-- no debconf information
--- End Message ---
--- Begin Message ---
Closing the bug since after investigation, the TLP service was masked.
Regards,
--
Raphaƫl Halimi
--- End Message ---