Doris-Breakwater commented on issue #70877:
URL: https://github.com/apache/doris/issues/70877#issuecomment-7095985358

   Breakwater-GitHub-Analysis-Slot: slot_efb345db5a1c
   
   The reported increase from sub-second latency to 124 seconds warrants 
investigating ANN coverage on the full-compaction output. I reviewed the source 
at the reported commit, `7126cf65d96`. The cause of the reported coverage loss 
is still open. Please clarify whether the count of 68 comes from the query 
profile or from inspecting the active segments’ index files.
   
   ### What the source confirms
   
   - **Full compaction can rebuild ANN.** It rewrites segments and takes its 
output schema from the highest-schema-version input rowset. When that schema 
declares the ANN index, both segment writers build it during finalization. The 
ANN writer deliberately omits segments below `max(FAISS training minimum, 
ann_index_build_min_segment_rows)`. For HNSW/SQ8 the training minimum is one 
row and the BE setting defaults to zero, so under defaults the size rule cannot 
explain an omitted index on a nonempty output segment. [Compaction schema 
selection](https://github.com/apache/doris/blob/7126cf65d96ebc43fce0906f51e92c1a2ccf24a6/be/src/storage/compaction/compaction.cpp#L501-L529),
 [ANN 
writer](https://github.com/apache/doris/blob/7126cf65d96ebc43fce0906f51e92c1a2ccf24a6/be/src/storage/index/ann/ann_index_writer.cpp#L135-L171),
 [FAISS training 
minimum](https://github.com/apache/doris/blob/7126cf65d96ebc43fce0906f51e92c1a2ccf24a6/be/src/storage/index/ann/faiss_ann_index.cpp#L501-L525).
   - **The duplicate DDL and the short jobs need to be correlated.** A 
same-name `CREATE INDEX` or `ALTER TABLE … ADD INDEX` raises an already-exists 
error. With `IF NOT EXISTS`, it returns before creating any job. On the local 
light-index path, the initial `CREATE INDEX` adds the definition and an 
explicit `BUILD INDEX` can queue the backfill. That job is displayed as `ADD 
INDEX` in `SHOW BUILD INDEX`. Its BE task skips active rowsets that already 
declare the ANN index ID and can finish successfully with an empty candidate 
list. That check uses schema metadata and cannot certify that the segment index 
entries are present or readable. This is the limitation described in #69816. 
[Duplicate 
check](https://github.com/apache/doris/blob/7126cf65d96ebc43fce0906f51e92c1a2ccf24a6/fe/fe-core/src/main/java/org/apache/doris/alter/SchemaChangeHandler.java#L2826-L2836),
 [Job 
display](https://github.com/apache/doris/blob/7126cf65d96ebc43fce0906f51e92c1a2ccf24a6/fe/fe-core/src/main/java/org/apach
 e/doris/alter/IndexChangeJob.java#L543-L571), [BE rowset 
selection](https://github.com/apache/doris/blob/7126cf65d96ebc43fce0906f51e92c1a2ccf24a6/be/src/storage/tablet/tablet.cpp#L1283-L1311).
   - **The profile counter has several causes.** ANN Top-N increments the 
fallback counter when there is no ANN reader, when loading the index fails, or 
when the query takes a fallback branch such as the small-candidate check. If 68 
is `AnnIndexFallbackBruteForceCnt`, it counts fallback events and cannot 
identify which segments lost physical coverage. [Top-N fallback 
logic](https://github.com/apache/doris/blob/7126cf65d96ebc43fce0906f51e92c1a2ccf24a6/be/src/storage/segment/segment_iterator.cpp#L877-L975).
   
   ### Evidence to collect before a repair attempt
   
   1. Share one affected tablet and, if available, one unaffected tablet. For 
each, include the BE build SHA, full-compaction response and tablet-level task 
result, input/output rowset IDs and version ranges, and each active output 
segment’s row count, rowset schema version, ANN index ID, and whether its ANN 
file or compound-file entry can be opened. The table-level POST acknowledges 
submission, so the per-tablet result matters. Include the effective 
`ann_index_build_min_segment_rows` on those BEs and the compaction-window log 
lines containing `Create a new faiss index`, `Skipping index building`, or a 
build error.
   2. Share paired before/after `EXPLAIN VERBOSE` and full query profiles with 
query IDs and per-BE scan details. Use the same precomputed query vector if 
possible to isolate the ANN scan from `EMBED`. Include `NumSegmentTotal`, 
`AnnIndexTopNSearchCnt`, `AnnIndexFallbackBruteForceCnt`, 
`AnnIndexTopNFallbackBySmallCandidateCnt`, ANN load/search time, scan CPU and 
I/O, and any ANN reader warnings. Please identify the source and time of the 
186 and 187 totals so we can match the same snapshot.
   3. Share the exact initial and repeat SQL, client responses, FE build SHA 
and `enable_light_index_change` setting, and the matching `SHOW BUILD INDEX` 
job IDs and FE audit entries. If the short jobs were explicit builds, look for 
`_input_rowsets is empty` on their BEs.
   
   For a maintainer repro, start with one tablet and multiple loaded rowsets, 
confirm ANN searches before compaction, then run tablet-level full compaction 
and inspect the new rowset before any rebuild. If an eligible nonempty output 
segment declares the index ID but its ANN entry is missing or unreadable, that 
gives a concrete compaction failure to reproduce and also explains why 
repeating `BUILD INDEX` can finish without repairing it. A segment whose rowset 
lacks the index ID can instead qualify for an explicit build.
   


-- 
This is an automated message from the Apache Git Service.
To respond to the message, please log on to GitHub and use the
URL above to go to the specific comment.

To unsubscribe, e-mail: [email protected]

For queries about this service, please contact Infrastructure at:
[email protected]


---------------------------------------------------------------------
To unsubscribe, e-mail: [email protected]
For additional commands, e-mail: [email protected]

Reply via email to