cygnusdark opened a new issue, #149:
URL: https://github.com/apache/doris-flink-connector/issues/149

   ### Search before asking
   
   - [X] I had searched in the 
[issues](https://github.com/apache/incubator-doris/issues?q=is%3Aissue) and 
found no similar issues.
   
   
   ### Version
   
   1.4.0
   
   ### What's Wrong?
   
   CDCTools job cannot restart from previous checkpoint/savepoint when multiple 
tables in sync.
   
   ### What You Expected?
   
   The job should be able to use previous checkpoint/savepoint to restart.
   
   ### How to Reproduce?
   
   To reproduce, sync multiple tables, for example:
   --including-tables test|test2|test_clone|test_clone2
   
   The reason is that Flink is a stateful application, and it is recommended by 
official that each stateful operator should have a unique uid.
   I fixed this issue by using table name as the uid of its associated sink 
operators.
   
   ### Anything Else?
   
   _No response_
   
   ### Are you willing to submit PR?
   
   - [X] Yes I am willing to submit a PR!
   
   ### Code of Conduct
   
   - [X] I agree to follow this project's [Code of 
Conduct](https://www.apache.org/foundation/policies/conduct)
   


-- 