On Tue, Mar 28, 2023 at 04:17:21PM +0530, sarveshwar k wrote: > I have attached a screenshot of my observation. When the current time is > 4:11:17, the Ref time is 4:11:15 (as mentioned in tracking output). > [image: image.png]
This is similar to the LastRx issue you reported before. The timestamp is intentionally adjusted by a small random value to make it more difficult to predict receive timestamps in the NTP symmetric mode. It's not necessary with a reference clock, but it's simpler do it always. -- Miroslav Lichvar -- To unsubscribe email [email protected] with "unsubscribe" in the subject. For help email [email protected] with "help" in the subject. Trouble? Email [email protected].