https://sourceware.org/bugzilla/show_bug.cgi?id=23169
--- Comment #13 from H.J. Lu <hjl.tools at gmail dot com> --- X86 linker uses a trick to use the PLT entry of IFUNC function in position-dependent executable as the function address for ALL internal and external references. We can do that because the PLT entry doesn't need ANY dynamic relocation. -- You are receiving this mail because: You are on the CC list for the bug.