Also allowing the bind-addresse can increase the security but not listening
on external connection

Chet Ramey <chet.ra...@case.edu> schrieb am Fr., 7. Jan. 2022, 16:54:

> On 1/7/22 10:52 AM, Dzogovic Vehbo wrote:
> > When you enter the time wait, you can't rebind again, since the
> socketopt
> > is defined after bind. By moving it up before the bind, you client sock
> > will still enter the TIME_WAIT after closing the fb, but you can rebind.
>
> OK, I see.
>
> Chet
>
> --
> ``The lyf so short, the craft so long to lerne.'' - Chaucer
>                  ``Ars longa, vita brevis'' - Hippocrates
> Chet Ramey, UTech, CWRU    c...@case.edu    http://tiswww.cwru.edu/~chet/
>