Thank you so much for replying to me queries;

I have sorted out both of the problems, in case it might help anyone else:

DTMF: In 'Manage Accounts - Media' de-select 'Send inband DTMF' and change the codec order so that G722 is above opus Sipgate: In 'Manage Accounts - Server Settings' de-select 'Always use the proxy server for outgoing sessions' (selected by default).

I have a further query:

If there is no access to a tray icon (for example on my Pinephone) how do you raise (show) a running version of Blink instead of starting a new instance? NB Pinephone is running Wayland.

Thanks again

On 10/08/21 11:39, Tijmen de Mes wrote:
Hi,

Can you enable 'Trace SIP’ and check how the MWI message looks like?

Best regards,

Tijmen de Mes
—
AG Projects

Op 9 aug. 2021, om 17:17 heeft Andrew Myers <[email protected]> het 
volgende geschreven:

So I have installed blink on Arch linux and it seems to be working with some 
exceptions:

The "Send inband DTMF" option does not seem to change the DTMF type.
Setting
         rtp:
             inband_dtmf = true or false
                                 in the config file seems to make no difference.

For some reason I cannot register my sipgate account:

ERROR    [main] Unhandled exception in notification observer 
Account('[email protected]') while handling notification 
'MWISubscriptionGotNotify'
ERROR    [main] Traceback (most recent call last):
ERROR    [main]   File 
"/usr/lib/python3.9/site-packages/sipsimple/configuration/datatypes.py", line 
186, in __new__
ERROR    [main]     username, domain = address.split('@')
ERROR    [main] ValueError: not enough values to unpack (expected 2, got 1)
ERROR    [main]
ERROR    [main] During handling of the above exception, another exception 
occurred:
ERROR    [main]
ERROR    [main] Traceback (most recent call last):
ERROR    [main]   File 
"/usr/lib/python3.9/site-packages/application/notification.py", line 206, in 
post_notification
ERROR    [main]     observer.handle_notification(notification)
ERROR    [main]   File 
"/usr/lib/python3.9/site-packages/sipsimple/account/__init__.py", line 361, in 
handle_notification
ERROR    [main]     handler(notification)
ERROR    [main]   File 
"/usr/lib/python3.9/site-packages/sipsimple/account/__init__.py", line 388, in 
_NH_MWISubscriptionGotNotify
ERROR    [main]     self._mwi_voicemail_uri = message_summary.message_account 
and SIPAddress(message_summary.message_account.replace('sip:', '', 1)) or None
ERROR    [main]   File 
"/usr/lib/python3.9/site-packages/sipsimple/configuration/datatypes.py", line 
189, in __new__
ERROR    [main]     raise ValueError("illegal SIP address: %s, must be in 
user@domain format" % address)
ERROR    [main] ValueError: illegal SIP address: 55000, must be in user@domain 
format


_______________________________________________
Blink mailing list
[email protected]
https://lists.ag-projects.com/mailman/listinfo/blink
_______________________________________________
Blink mailing list
[email protected]
https://lists.ag-projects.com/mailman/listinfo/blink

_______________________________________________
Blink mailing list
[email protected]
https://lists.ag-projects.com/mailman/listinfo/blink

Reply via email to