Hi Gerry, On Wednesday 21 January 2009 23:40:26 Gerry Creager wrote: > History/background/description of the cluster > * 126 node Dell 1950 cluster with dual-quad core Xeons > * bnx2 module loaded for the Broadcom onboard nics
> Received disconnect from 192.168.200.154: 2: Bad packet length 808464432. It may also be worth making sure you're using the latest bnx2 version. $(modinfo bnx2) should give you that, the latest one being 1.7.6b3. I've been using those PE1950 a while, and had my share of weird issues with them, including complete kernel panics on high traffic load. Upgrading to the Dell-provided bnx2 version proved helpful. If you use SuSE or a Redhat-ish distro, the Dell Linux repository <http://linux.dell.com/repo/hardware/> may be useful, and upgrading the module version would be extremely simple to handle with the help of DKMS. Cheers, -- Kilian _______________________________________________ Beowulf mailing list, [email protected] To change your subscription (digest mode or unsubscribe) visit http://www.beowulf.org/mailman/listinfo/beowulf