I have following output from ibcheckerrors utility:

c5ws7:/home/guest # ibcheckerrors
#warn: counter LinkDowned = 20  (threshold 10)
Error check on lid 1 (MT47396 Infiniscale-III Mellanox Technologies) port all: FAILED
#warn: counter LinkDowned = 13  (threshold 10)
Error check on lid 1 (MT47396 Infiniscale-III Mellanox Technologies) port 8: FAILED
# Checked Switch: nodeguid 0x000b8cffff004037 with failure

LID 1 corresponds to our 24-port Flextronics F-X43044 switch. Does this output means that there may be potential problems w/ port 8 or whole switch ?

Mikhail Kuzminsky
Computer Assistance to Chemical Research Center
Zelinsky Inst. of Organic Chemistry
Moscow
_______________________________________________
Beowulf mailing list, Beowulf@beowulf.org
To change your subscription (digest mode or unsubscribe) visit 
http://www.beowulf.org/mailman/listinfo/beowulf

Reply via email to