Bruce Allen <[EMAIL PROTECTED]> writes:

> When I buy RAID controllers, I put this requirement directly in my bid
> specifications.  I say something like the following:
>
> ------------------------------------------------------------------
>
> During a READ operation, if the RAID controller finds an unreadable
> (uncorrectable) disk sector, then it will immediately reconstruct the
> missing data for that sector using redundant data from the rest of the
> array, and WRITE that data to the unreadable (uncorrectable) sector to
> force sector reallocation if needed by the disk.
>
> In addition, the RAID controller will perform a continous or regular
> (at least daily) background scan of all disk sectors to identify and
> repair any unreadable sectors as described above.
>
> ------------------------------------------------------------------

I think you should add a parity verification to this - not just a
sector scan.

-- 
Leif Nixon                       -            Systems expert
------------------------------------------------------------
National Supercomputer Centre    -      Linkoping University
------------------------------------------------------------
_______________________________________________