Hi,

On 14.03.19 22:12, Radosław Korzeniewski wrote:
Hello,

czw., 14 mar 2019 o 16:05 Thorsten Johannsen <[email protected] <mailto:[email protected]>> napisał(a):

    (...) inside volume for jobID 5269 (...)

There is no such functionality in Bacula as described above. You cannot reserve or dedicate a volume for particular jobid.

All you can do is a dedicate a pool of volumes for a Job.

Oh dear, then my whole concept just blew up. But can you point me at my logical error?

In my mind, if

- Volume autolabel is enabled

- Maximum jobs per volume is set to 1

- Recycling of volumes is disabled


Bacula would be forced to create (label) a new volume for each job, wouldn't it? Where am I wrong here?


Thanks in advance for your input!


Cheers, Thorsten


_______________________________________________
Bacula-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bacula-users

Reply via email to