On 01/15/2014 12:48 PM, Luis G. Alford G. wrote:
> Hi
>
> I have installed a bacula server and it works ok but when I reboot the
> server the tape drive change's it's scsi address when I reboot the
> server it is via FC . any idea what i can do to avoid this from happen
>
There are probably several ways to solve this, but one of them is to use
the /dev/tape/by-id/* names instead of the /dev/nst0 naming.
>From my bacula-sd.conf:
Autochanger {
Name = HP-ML4048
Device = LTO4-Drive-1, LTO4-Drive-2
Changer Command = "/opt/bacula/scripts/mtx-changer %c %o %S %a %d"
Changer Device = /dev/tape/by-id/scsi-3500110a0008dde58
}
Device {
Name = LTO4-Drive-1
Drive Index = 0
Media Type = LTO-4
Archive Device = /dev/tape/by-id/scsi-3500110a0008dde59-nst
...
}
Device {
Name = LTO4-Drive-2
Drive Index = 1
Media Type = LTO-4
Archive Device = /dev/tape/by-id/scsi-3500110a0008dde5f-nst
...
}
The by-id name will not change between reboots.
-Thomas
------------------------------------------------------------------------------