Hi,
10.10.2007 09:05,, Louis Joly wrote::
> When my Volumes are recycled, how relabeled them automatically
Basically, the answer is "you don't".
I understand that for file storage that coud be used effectively, but
tapes with barcodes labels are not easily relabeld using software :-)
> Device {
> Name = DEV_FileStorageFull
> Media Type = File
> Archive Device = /data/bacula/backups/monthly
> LabelMedia = yes; # lets Bacula label unlabeled media
> Random Access = Yes;
> AutomaticMount = yes; # when device opened, read it
> RemovableMedia = no;
> AlwaysOpen = yes;
> }
>
> Pool {
> Name = POOL_Full
> Pool Type = Backup
> Recycle = yes # Bacula can automatically recycle
> Volumes
> AutoPrune = yes # Prune expired volumes
> Volume Retention = 6 months
> Maximum Volume Jobs = 1
> Label Format = "Full-${Year}-${Month:p/2/0/r}-${Day:p/2/0/r}"
> Maximum Volumes = 9
> }
Note that the "Label Format" option is deprecated.
Arno
--
Arno Lehmann
IT-Service Lehmann
www.its-lehmann.de
-------------------------------------------------------------------------
This SF.net email is sponsored by: Splunk Inc.
Still grepping through log files to find problems? Stop.
Now Search log events and configuration files using AJAX and a browser.
Download your FREE copy of Splunk now >> http://get.splunk.com/
_______________________________________________
Bacula-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bacula-users