I have recently noticed that my Magnum224 was not showing up all 24
slots specifically that the IMPORT/EXPORT slot (#24) was missing.
As a result
Connecting to Storage daemon DEV6-Changer at dev6.radimg.pitt.edu:9103 ...
3306 Issuing autochanger "slots" command.
Device "Magnum224-0" has 24 slots.
Connecting to Storage daemon DEV6-Changer at dev6.radimg.pitt.edu:9103 ...
3306 Issuing autochanger "list" command.
Catalog record for Volume "A00030" updated to reference slot 1.
Catalog record for Volume "A00043" updated to reference slot 2.
Catalog record for Volume "A00032" updated to reference slot 3.
Catalog record for Volume "A00037" updated to reference slot 4.
Catalog record for Volume "A00023" updated to reference slot 5.
Catalog record for Volume "A00006" updated to reference slot 6.
Catalog record for Volume "A00007" updated to reference slot 7.
Catalog record for Volume "A00008" updated to reference slot 8.
Catalog record for Volume "A00028" updated to reference slot 9.
Catalog record for Volume "A00010" updated to reference slot 10.
Catalog record for Volume "A00038" updated to reference slot 11.
Catalog record for Volume "A00039" updated to reference slot 12.
Catalog record for Volume "A00040" updated to reference slot 13.
Catalog record for Volume "A00012" updated to reference slot 14.
Catalog record for Volume "A00017" updated to reference slot 15.
Catalog record for Volume "A00016" updated to reference slot 16.
Catalog record for Volume "A00041" updated to reference slot 17.
Catalog record for Volume "A00042" updated to reference slot 18.
Catalog record for Volume "A00036" updated to reference slot 19.
Catalog record for Volume "A00018" updated to reference slot 20.
Catalog record for Volume "A00027" updated to reference slot 21.
Catalog record for Volume "A00034" updated to reference slot 22.
Catalog record for Volume "A00031" updated to reference slot 23.
After some investigation the problem is the output of the mtx script:
Storage Changer /dev/autochanger1:2 Drives, 24 Slots ( 1 Import/Export )
Data Transfer Element 0:Empty
Data Transfer Element 1:Empty
Storage Element 1:Full :VolumeTag=A00030
Storage Element 2:Full :VolumeTag=A00043
Storage Element 3:Full :VolumeTag=A00032
Storage Element 4:Full :VolumeTag=A00037
Storage Element 5:Full :VolumeTag=A00023
Storage Element 6:Full :VolumeTag=A00006
Storage Element 7:Full :VolumeTag=A00007
Storage Element 8:Full :VolumeTag=A00008
Storage Element 9:Full :VolumeTag=A00028
Storage Element 10:Full :VolumeTag=A00010
Storage Element 11:Full :VolumeTag=A00038
Storage Element 12:Full :VolumeTag=A00039
Storage Element 13:Full :VolumeTag=A00040
Storage Element 14:Full :VolumeTag=A00012
Storage Element 15:Full :VolumeTag=A00017
Storage Element 16:Full :VolumeTag=A00016
Storage Element 17:Full :VolumeTag=A00041
Storage Element 18:Full :VolumeTag=A00042
Storage Element 19:Full :VolumeTag=A00036
Storage Element 20:Full :VolumeTag=A00018
Storage Element 21:Full :VolumeTag=A00027
Storage Element 22:Full :VolumeTag=A00034
Storage Element 23:Full :VolumeTag=A00031
Storage Element 24 IMPORT/EXPORT:Full :VolumeTag=A00035
The mtx script expects the slot number followed by a :Full:
If it does not see that it ignores the slot.
My fix was to use sed to remove the " IMPORT/EXPORT" from the stream
so that the rest of the processing would work.
Replace this line:
${MTX} -f $ctl status >${TMPFILE}
With this:
${MTX} -f $ctl status | sed 's# IMPORT/EXPORT##g' >${TMPFILE}
And then the result is:
Device "Magnum224-0" has 24 slots.
Connecting to Storage daemon DEV6-Changer at dev6.radimg.pitt.edu:9103 ...
3306 Issuing autochanger "list" command.
Catalog record for Volume "A00030" updated to reference slot 1.
Catalog record for Volume "A00043" updated to reference slot 2.
Catalog record for Volume "A00032" updated to reference slot 3.
Catalog record for Volume "A00037" updated to reference slot 4.
Catalog record for Volume "A00023" updated to reference slot 5.
Catalog record for Volume "A00006" updated to reference slot 6.
Catalog record for Volume "A00007" updated to reference slot 7.
Catalog record for Volume "A00008" updated to reference slot 8.
Catalog record for Volume "A00028" updated to reference slot 9.
Catalog record for Volume "A00010" updated to reference slot 10.
Catalog record for Volume "A00038" updated to reference slot 11.
Catalog record for Volume "A00039" updated to reference slot 12.
Catalog record for Volume "A00040" updated to reference slot 13.
Catalog record for Volume "A00012" updated to reference slot 14.
Catalog record for Volume "A00017" updated to reference slot 15.
Catalog record for Volume "A00016" updated to reference slot 16.
Catalog record for Volume "A00041" updated to reference slot 17.
Catalog record for Volume "A00042" updated to reference slot 18.
Catalog record for Volume "A00036" updated to reference slot 19.
Catalog record for Volume "A00018" updated to reference slot 20.
Catalog record for Volume "A00027" updated to reference slot 21.
Catalog record for Volume "A00034" updated to reference slot 22.
Catalog record for Volume "A00031" updated to reference slot 23.
Catalog record for Volume "A00035" updated to reference slot 24.
--
John M. Drescher
-------------------------------------------------------------------------