About the tray monitor, try the configuration changes
Robert Nelson instructed a few days ago:
---
In the file /etc/bacula/bacula-dir.conf add the
following lines to the Console resource at the end of
the file after the line "CommandACL = status,
.status".
CatalogACL = *all*
JobACL = *all*
ClientACL = *all*
StorageACL = *all*
ScheduleACL = *all*
PoolACL = *all*
FileSetACL = *all*
If you want to create different console "users" you
can create multiple entries with different ACL values.
---
I followed his advice and then it worked fine.
As for the second problem, it happens on my server as
well. Regards,
Georger
--- Andrei Mikhailovsky <[EMAIL PROTECTED]> escreveu:
>
> Hi
>
> I've recently upgraded bacula from 1.36.3 to 1.38.9.
> Now the tray
> monitor shows "You must specify a "use
> <catalog-name>" command before
> continuing." instead of Director status. Does anyone
> know what have I
> done wrong?
>
> Also, there seems to be a bug in the
> bacula-gnome-console versions
> 1.36.3 and the latest 1.38.9. Whenever bacula server
> is restarted, the
> console crashes with segfault and needs a restart.
>
> Andrei
_______________________________________________________
Navegue com o Yahoo! Acesso Grátis, assista aos jogos do Brasil na Copa e ganhe
prêmios de hora em hora!
http://br.yahoo.com/artilheirodacopa/
-------------------------------------------------------
Using Tomcat but need to do more? Need to support web services, security?
Get stuff done quickly with pre-integrated technology to make your job easier
Download IBM WebSphere Application Server v.1.0.1 based on Apache Geronimo
http://sel.as-us.falkag.net/sel?cmd=lnk&kid=120709&bid=263057&dat=121642
_______________________________________________
Bacula-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/bacula-users