Hello,
the following has been discussed before. I was able to reproduce the
following:
I use a 6-slot autoloader.
I have a query to report which tapes are loaded in the slots.
I insert a magazine with six cartridges and do 'update slots scan
storage=HPDAT"
After that, the query correctly reports the tapes in all six slots.
The backup running first uses the tape already loaded in the drive after
the scan.
One tape is filled, bacula changes the tape, but now the report doesn't
show the tape just unloaded.
When I manually update the volume information, everything goes as expected.
When I manually unload the tape from the drive before the job requests a
tape, everything works normal, too: bacula sees the drive is empty and
loads a tape automatically.
Could somebody verify this?
Arno
--
IT-Service Lehmann [EMAIL PROTECTED]