2009/10/23 Spiros Ioannou <[email protected]>: > Hello dear developers, > We recently bought a Quantum Scalar50 with 76 slots and 2 LTO-4 drivs. These > are two Scalar50 units connected together, drives go to the bottom unit and > the other unit serves as extra slots. mtx is 1.3.12, OS is CentOS 5.3 > > At first, mtx-changer (bacula 3.0.1) didn't recognize most of the slots > because 72 of them are marked as IMPORT/EXPORT except for the first 4. mtx > status: > Data Transfer Element 0:Full (Unknown Storage Element Loaded):VolumeTag = > ACW964L4 > Data Transfer Element 1:Empty > Storage Element 1:Empty > Storage Element 2:Full :VolumeTag=ACW971L4 > Storage Element 3:Empty > Storage Element 4:Empty > Storage Element 5 IMPORT/EXPORT:Empty > Storage Element 6 IMPORT/EXPORT:Full :VolumeTag=ACW970L4 > ... > Storage Element 74 IMPORT/EXPORT:Full :VolumeTag=ACW974L4 > Storage Element 75 IMPORT/EXPORT:Full :VolumeTag=ACW973L4 > Storage Element 76 IMPORT/EXPORT:Full :VolumeTag=ACW972L4 > > After changing the mtx-changer script to ignore the IMPORT/EXPORT I realized > that the robot doesn't keep correct track of the loaded slot: > 1) If the slot gets loaded to a drive directly from an IMPORT/EXPORT (I/E) > slot (i.e. slot >4) then it is reported as coming from a random free non-I/E > slot (1-4) if an empty I/E slot is found. For example if slot 3 is empty and > a load element 70 to drive it gets reported as coming from slot 3. So when > you unload it (with mtx) it goes back to 3 and not to 70. > 2) If all non-I/E slots 1-4 were full when loading a tape from an I/E slot > it is reported as "Unknown storage element" like in the example above, > breaking the "loaded?" command > > Issuing "label barcodes" fails because bacula thinks drive0 with the > "unknown" element is empty because of the bad parsing. I fear that if i > modify mtx-changer any further to trick it in seeing the unknown element as > a random "empty" slot number, something will break in bacula. > > Is there a way to make bacula keep track of tapes using just the barcode > labels and ignore slots? I presume this is what happens with commercial > software. > > Any more thoughts? >
I believe I remember someone getting around this behavior by heavy modification of the mtx-changer and also having mtx-changer query the bacula database. I can not find the solution however. A second option is the autochanger may have an option for output. And a third option would be to investigate this issue with the writers of mtx perhaps there is new mtx that better works with your changer. John John ------------------------------------------------------------------------------ Come build with us! The BlackBerry(R) Developer Conference in SF, CA is the only developer event you need to attend this year. Jumpstart your developing skills, take BlackBerry mobile applications to market and stay ahead of the curve. Join us from November 9 - 12, 2009. Register now! http://p.sf.net/sfu/devconference _______________________________________________ Bacula-devel mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/bacula-devel